The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3

dc.contributor.authorCastro, Nuno Filipe
dc.contributor.authorOnofre, A.
dc.contributor.authorATLAS Collaboration
dc.date.accessioned2025-12-24T08:41:44Z
dc.date.issued2024
dc.description.abstractThe ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of \( \mathcal{L} = 2 \times 10^{34} \, \text{cm}^{-2} \, \text{s}^{-1} \) was routinely achieved at the start of fills, twice the design luminosity. For Run 3, accelerator improvements, notably luminosity levelling, allow sustained running at an instantaneous luminosity of \( \mathcal{L} = 2 \times 10^{34} \, \text{cm}^{-2} \, \text{s}^{-1} \), with an average of up to 60 interactions per bunch crossing. The ATLAS detector has been upgraded to recover Run 1 single-lepton trigger thresholds while operating comfortably under Run 3 sustained pileup conditions. A fourth pixel layer 3.3 cm from the beam axis was added before Run 2 to improve vertex reconstruction and b-tagging performance. New Liquid Argon Calorimeter digital trigger electronics, with corresponding upgrades to the Trigger and Data Acquisition system, take advantage of a factor of 10 finer granularity to improve triggering on electrons, photons, taus, and hadronic signatures through increased pileup rejection. The inner muon endcap wheels were replaced by New Small Wheels with Micromegas and small-strip Thin Gap Chamber detectors, providing both precision tracking and Level-1 Muon trigger functionality. Trigger coverage of the inner barrel muon layer near one endcap region was augmented with modules integrating new thin-gap resistive plate chambers and smaller-diameter drift-tube chambers. Tile Calorimeter scintillation counters were added to improve electron energy resolution and background rejection. Upgrades to Minimum Bias Trigger Scintillators and Forward Detectors improve luminosity monitoring and enable total proton-proton cross section, diffractive physics, and heavy ion measurements. These upgrades are all compatible with operation in the much harsher environment anticipated after the High-Luminosity upgrade of the LHC and are the first steps towards preparing ATLAS for the High-Luminosity upgrade of the LHC. This paper describes the Run 3 configuration of the ATLAS detector.eng
dc.distributioninternational
dc.identifier.citationAad, G., Abbott, B., Abbott, D. C., Abdallah, J., Abeling, K., Abidi, S. H., . . . Collaboration, A. (2024). The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3. Journal of Instrumentation, 19(5). doi: 10.1088/1748-0221/19/05/p05063
dc.identifier.doi10.1088/1748-0221/19/05/p05063
dc.identifier.eissn1748-0221
dc.identifier.urihttps://hdl.handle.net/1822/98727
dc.language.isoeng
dc.peerreviewedyes
dc.publisherIOP Publishing
dc.relation.hasversionhttps://iopscience.iop.org/article/10.1088/1748-0221/19/05/P05063
dc.rightsopenAccess
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectCalorimeter methodspor
dc.subjectLarge detector systems for particle and astroparticle physicspor
dc.subjectMuon spectrometerspor
dc.subjectParticle tracking detectorspor
dc.subject.fosCiências Naturais::Ciências Físicas
dc.titleThe ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3eng
dc.typearticle
dspace.entity.typePublication
oaire.citationIssue5por
oaire.citationVolume19por
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
sdum.journalJournal of Instrumentation

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
Aad_2024_J._Inst._19_P05063.pdf
Tamanho:
49.66 MB
Formato:
Adobe Portable Document Format