Inconsistency in shoulder arthrometers for measuring glenohumeral joint laxity: a systematic review

dc.commentshttp://3bs.uminho.pt/node/20952por
dc.contributor.authorGomes, Eluanapor
dc.contributor.authorAndrade, Renatopor
dc.contributor.authorValente, Cristinapor
dc.contributor.authorSantos, J. Victorpor
dc.contributor.authorNunes, Jónipor
dc.contributor.authorCarvalho, Óscar Samuel Novaispor
dc.contributor.authorCorrelo, V. M.por
dc.contributor.authorSilva, Filipe S.por
dc.contributor.authorOliveira, Joaquim M.por
dc.contributor.authorReis, R. L.por
dc.contributor.authorEspregueira-Mendes, Joãopor
dc.date.accessioned2023-07-26T14:13:37Z
dc.date.available2023-07-26T14:13:37Z
dc.date.issued2023-07
dc.date.updated2023-07-20T11:04:15Z
dc.description.abstractThere is no consensus on how to measure shoulder joint laxity and results reported in the literature are not well systematized for the available shoulder arthrometer devices. This systematic review aims to summarize the results of currently available shoulder arthrometers for measuring glenohumeral laxity in individuals with healthy or injured shoulders. Searches were conducted on the PubMed, EMBASE, and Web of Science databases to identify studies that measure glenohumeral laxity with arthrometer-assisted assessment. The mean and standard deviations of the laxity measurement from each study were compared based on the type of population and arthrometer used. Data were organized according to the testing characteristics. A total of 23 studies were included and comprised 1162 shoulders. Populations were divided into 401 healthy individuals, 278 athletes with asymptomatic shoulder, and 134 individuals with symptomatic shoulder. Sensors were the most used method for measuring glenohumeral laxity and stiffness. Most arthrometers applied an external force to the humeral head or superior humerus by a manual-assisted mechanism. Glenohumeral laxity and stiffness were mostly assessed in the sagittal plane. There is substantial heterogeneity in glenohumeral laxity values that is mostly related to the arthrometer used and the testing conditions. This variability can lead to inconsistent results and influence the diagnosis and treatment decision-making.por
dc.description.sponsorshipThis article is a result of the project DILATO (reference 47289) supported by the Norte Portugal Regional Operational Programme (NORTE 2020), under the PORTUGAL 2020 Partnership Agreement, through the European Regional Development Fund (ERDF).por
dc.distributioninternationalpor
dc.identifier.articlenumber799por
dc.identifier.citationGomes E., Andrade R., Valente C., Victor Santos J., Nunos J., Carvalho O., Correlo V. M., Silva F. S., Oliveira J. M., Reis R. L., Espregueira-Mendes J. D. Inconsistency in Shoulder Arthrometers for Measuring Glenohumeral Joint Laxity: A Systematic Review , Bioengineering, Vol. 10, Issue 7, pp. 799, 2306-5354, 2023por
dc.identifier.doi10.3390/bioengineering10070799por
dc.identifier.eissn2306-5354por
dc.identifier.urihttps://hdl.handle.net/1822/85738
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)por
dc.relation.publisherversionhttps://www.mdpi.com/2306-5354/10/7/799por
dc.rightsopenAccesspor
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/por
dc.subjectArthrometerpor
dc.subjectLaxitypor
dc.subjectShoulderpor
dc.subjectStiffnesspor
dc.subjectglenohumeralpor
dc.titleInconsistency in shoulder arthrometers for measuring glenohumeral joint laxity: a systematic reviewpor
dc.typearticle
dspace.entity.typePublicationen
oaire.citationEndPage16por
oaire.citationIssue7por
oaire.citationStartPage1por
oaire.citationVolume10por
oaire.versionVoRpor
sdum.journalBioengineeringpor

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
20952-bioengineering-10-00799.pdf
Tamanho:
1.54 MB
Formato:
Adobe Portable Document Format