Intraocular pressure after implantation of the Vsian Implantable Collamer Lens with CentraFLOW without iridotomy
| dc.contributor.author | Higueras-Esteban, Alejandro | |
| dc.contributor.author | Ortiz-Gomariz, Amanda | |
| dc.contributor.author | Gutiérrez, Ángel Ramón | |
| dc.contributor.author | Villa-Collar, César | |
| dc.contributor.author | Abad-Montes, Juan P. | |
| dc.contributor.author | Fernandes, Paulo Rodrigues | |
| dc.contributor.author | González-Méijome, José Manuel | |
| dc.date.accessioned | 2013-12-13T15:20:09Z | |
| dc.date.available | 2013-12-13T15:20:09Z | |
| dc.date.issued | 2013 | |
| dc.date.updated | 2013-11-22T14:04:02Z | |
| dc.description.abstract | PURPOSE: To compare the intraocular pressure (IOP) values during a 3-month period after implantation of the new Visian Implantable Collamer Lens (ICL; STAAR Surgical Company, Nidau, Switzerland) V4c design with CentraFLOW technology without iridotomy using a standard procedure followed by implantation of the conventional ICL V4b model. | eng |
| dc.description.sponsorship | ALL AUTHORS HAVE COMPLETED AND SUBMITTED THE ICMJE FORM FOR DISCLOSURE OF POTENTIAL CONFLICTS OF INTEREST and none were reported. Supported in part by a grant from the Spanish Ministry of Health, Instituto Carlos III, Red Temitica de Investigacion Cooperativa en Salud Patologia Ocular del Envejecimiento, Calidad Visual y Calidad de Vida, Subproyecto de Calidad Visual, Madrid, Spain (RD07/0062). Involved in Design and conduct of study (A.H.-E., C.V.-C., R.G.-O., P.F., J.G.-M.); Collection, management, analysis, and interpretation of data (A.H.-E., J.G.-M., P.F.); and Preparation, review, or approval of manuscript (A.H.-E., A.O.-G., C.V.-C., R.G.-O., J.-A., P.F., J.G.-M.). | por |
| dc.distribution | international | por |
| dc.identifier.doi | 10.1016/j.ajo.2013.05.018 | |
| dc.identifier.issn | 0002-9394 | por |
| dc.identifier.pmid | 23876870 | por |
| dc.identifier.uri | https://hdl.handle.net/1822/27013 | |
| dc.language.iso | eng | por |
| dc.peerreviewed | yes | por |
| dc.publisher | Elsevier | por |
| dc.rights | openAccess | por |
| dc.subject.wos | Science & Technology | por |
| dc.title | Intraocular pressure after implantation of the Vsian Implantable Collamer Lens with CentraFLOW without iridotomy | por |
| dc.type | article | |
| dspace.entity.type | Publication | en |
| oaire.citationEndPage | 805 | por |
| oaire.citationIssue | 4 | por |
| oaire.citationStartPage | 800 | por |
| oaire.citationTitle | American Journal of Ophthalmology | por |
| oaire.citationVolume | 156 | por |
| sdum.journal | American Journal of Ophthalmology | por |
Ficheiros
Pacote original
1 - 1 de 1
A carregar...
- Nome:
- 5.5.89. HIGUERAS-ESTEBAN_13_AJO (ICL CentraFlow&OP).pdf
- Tamanho:
- 976.35 KB
- Formato:
- Adobe Portable Document Format