Intraocular pressure after implantation of the Vsian Implantable Collamer Lens with CentraFLOW without iridotomy

dc.contributor.authorHigueras-Esteban, Alejandro
dc.contributor.authorOrtiz-Gomariz, Amanda
dc.contributor.authorGutiérrez, Ángel Ramón
dc.contributor.authorVilla-Collar, César
dc.contributor.authorAbad-Montes, Juan P.
dc.contributor.authorFernandes, Paulo Rodrigues
dc.contributor.authorGonzález-Méijome, José Manuel
dc.date.accessioned2013-12-13T15:20:09Z
dc.date.available2013-12-13T15:20:09Z
dc.date.issued2013
dc.date.updated2013-11-22T14:04:02Z
dc.description.abstractPURPOSE: To compare the intraocular pressure (IOP) values during a 3-month period after implantation of the new Visian Implantable Collamer Lens (ICL; STAAR Surgical Company, Nidau, Switzerland) V4c design with CentraFLOW technology without iridotomy using a standard procedure followed by implantation of the conventional ICL V4b model.eng
dc.description.sponsorshipALL AUTHORS HAVE COMPLETED AND SUBMITTED THE ICMJE FORM FOR DISCLOSURE OF POTENTIAL CONFLICTS OF INTEREST and none were reported. Supported in part by a grant from the Spanish Ministry of Health, Instituto Carlos III, Red Temitica de Investigacion Cooperativa en Salud Patologia Ocular del Envejecimiento, Calidad Visual y Calidad de Vida, Subproyecto de Calidad Visual, Madrid, Spain (RD07/0062). Involved in Design and conduct of study (A.H.-E., C.V.-C., R.G.-O., P.F., J.G.-M.); Collection, management, analysis, and interpretation of data (A.H.-E., J.G.-M., P.F.); and Preparation, review, or approval of manuscript (A.H.-E., A.O.-G., C.V.-C., R.G.-O., J.-A., P.F., J.G.-M.).por
dc.distributioninternationalpor
dc.identifier.doi10.1016/j.ajo.2013.05.018
dc.identifier.issn0002-9394por
dc.identifier.pmid23876870por
dc.identifier.urihttps://hdl.handle.net/1822/27013
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherElsevierpor
dc.rightsopenAccesspor
dc.subject.wosScience & Technologypor
dc.titleIntraocular pressure after implantation of the Vsian Implantable Collamer Lens with CentraFLOW without iridotomypor
dc.typearticle
dspace.entity.typePublicationen
oaire.citationEndPage805por
oaire.citationIssue4por
oaire.citationStartPage800por
oaire.citationTitleAmerican Journal of Ophthalmologypor
oaire.citationVolume156por
sdum.journalAmerican Journal of Ophthalmologypor

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
5.5.89. HIGUERAS-ESTEBAN_13_AJO (ICL CentraFlow&OP).pdf
Tamanho:
976.35 KB
Formato:
Adobe Portable Document Format