Changes in choroidal thickness and retinal activity with a myopia control contact lens
| dc.contributor.author | Amorim-de-Sousa, Ana | |
| dc.contributor.author | Pauné, Jaume | |
| dc.contributor.author | Silva-Leite, Sara | |
| dc.contributor.author | Fernandes, Paulo | |
| dc.contributor.author | González-Méijome, José Manuel | |
| dc.contributor.author | Queirós, A. | |
| dc.date.accessioned | 2023-07-20T10:15:33Z | |
| dc.date.available | 2023-07-20T10:15:33Z | |
| dc.date.issued | 2023-05-23 | |
| dc.date.updated | 2023-06-09T13:01:05Z | |
| dc.description.abstract | Purpose: The axial elongation in myopia is associated with some structural and functional retinal changes. The purpose of this study was to investigate the effect of a contact lens (CL) intended for myopia control on the choroidal thickness (ChT) and the retinal electrical response. Methods: Ten myopic eyes (10 subjects, 18–35 years of age) with spherical equivalents from −0.75 to −6.00 diopters (D) were enrolled. The ChT at different eccentricities (3 mm temporal, 1.5 mm temporal, sub-foveal ChT, 1.5 mm nasal, and 3 mm nasal), the photopic 3.0 b-wave of ffERG and the PERG were recorded and compared with two material-matched contact lenses following 30 min of wear: a single-vision CL (SV) and a radial power gradient CL with +1.50 D addition (PG). Results: Compared with the SV, the PG increased the ChT at all eccentricities, with statistically significant differences at 3.0 mm temporal (10.30 ± 11.51 µm, <i>p</i> = 0.020), in sub-foveal ChT (17.00 ± 20.01 µm, <i>p</i> = 0.025), and at 1.5 mm nasal (10.70 ± 14.50 µm, <i>p</i> = 0.044). The PG decreased significantly the SV amplitude of the ffERG photopic b-wave (11.80 (30.55) µV, <i>p</i> = 0.047), N35-P50 (0.90 (0.96) µV, <i>p</i> = 0.017), and P50-N95 (0.46 (2.50) µV, <i>p</i> = 0.047). The amplitude of the a-wave was negatively correlated with the ChT at 3.0T (r = −0.606, <i>p</i> = 0.038) and 1.5T (r = −0.748, <i>p</i> = 0.013), and the amplitude of the b-wave showed a negative correlation with the ChT at 1.5T (r = −0.693, <i>p</i> = 0.026). Conclusions: The PG increased the ChT in a similar magnitude observed in previous studies. These CLs attenuated the amplitude of the retinal response, possibly due to the combined effect of the induced peripheral defocus high-order aberrations impacting the central retinal image. The decrease in the response of bipolar and ganglion cells suggests a potential retrograde feedback signaling effect from the inner to outer retinal layers observed in previous studies. | |
| dc.description.sponsorship | This work was funded by the Portuguese Foundation for Science and Technology (FCT) in the framework of projects PTDC/FIS-OPT/0677/2014, the FCT Strategic Funding UID/FIS/04650/2013, FCT-SFRH/BPD/92365/2013 and SFRH/BD/136684/2018. | |
| dc.identifier.citation | Amorim-de-Sousa, A.; Pauné, J.; Silva-Leite, S.; Fernandes, P.; Gozález-Méijome, J.M.; Queirós, A. Changes in Choroidal Thickness and Retinal Activity with a Myopia Control Contact Lens. J. Clin. Med. 2023, 12, 3618. https://doi.org/10.3390/jcm12113618 | |
| dc.identifier.doi | 10.3390/jcm12113618 | |
| dc.identifier.eissn | 2077-0383 | |
| dc.identifier.uri | https://hdl.handle.net/1822/85587 | |
| dc.language.iso | eng | |
| dc.peerreviewed | yes | |
| dc.publisher | Multidisciplinary Digital Publishing Institute | |
| dc.relation | info:eu-repo/grantAgreement/FCT/3599-PPCDT/PTDC%2FFIS-OPT%2F0677%2F2014/PT | |
| dc.relation | info:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UID%2FFIS%2F04650%2F2013/PT | |
| dc.relation | info:eu-repo/grantAgreement/FCT/FARH/SFRH%2FBPD%2F92365%2F2013/PT | |
| dc.relation | info:eu-repo/grantAgreement/FCT/POR_NORTE/SFRH%2FBD%2F136684%2F2018/PT | |
| dc.relation.publisherversion | https://www.mdpi.com/2077-0383/12/11/3618 | |
| dc.rights | openAccess | |
| dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
| dc.source.uri | https://creativecommons.org/licenses/by/4.0/ | |
| dc.subject | choroidal thickness | por |
| dc.subject | contact lens | por |
| dc.subject | ERG | por |
| dc.subject | myopia control | por |
| dc.subject | retinal activity | por |
| dc.title | Changes in choroidal thickness and retinal activity with a myopia control contact lens | eng |
| dc.type | article | |
| dspace.entity.type | Publication | en |
| oaire.citationIssue | 11 | |
| oaire.citationVolume | 12 | |
| sdum.journal | Journal of Clinical Medicine |
Ficheiros
Pacote original
1 - 1 de 1