Quasi-static tests on a two-story CLT building
| dc.contributor.author | Matos, Filipe Tiago | por |
| dc.contributor.author | Branco, Jorge M. | por |
| dc.contributor.author | Rocha, Patrício | por |
| dc.contributor.author | Demschner, Thomas | por |
| dc.contributor.author | Lourenço, Paulo B. | por |
| dc.date.accessioned | 2020-04-20T14:51:51Z | |
| dc.date.available | 2020-04-20T14:51:51Z | |
| dc.date.issued | 2019 | |
| dc.description.abstract | A two-story full-scale CLT building of 4.5 m x 9.1 m in plan, with a height of 5.04 m, was tested under quasi-static monotonic and cyclic loading for platform-type construction. The main objectives were to evaluate the global response of the structure, the performance of the shear walls, the behaviour of the connectors (hold-downs and angle brackets) and the frequency response of the structure during the tests. Lateral loads were applied on the storeys inducing torsion to the building. Loading procedure, number and disposition of connectors varied between tests. However, it is important to note that, in order to avoid a possible overlap of effects, the metal connectors hold-downs and angle-brackets only have been placed in CLT shear walls in each loading direction. In terms of performance, longitudinal direction presented a stiffer behaviour when compared to the transverse, where it was possible to verify greater sliding in the longitudinal direction and global rocking in the transverse direction. The results of this experimental campaign will be used for further analytical and numerical analyses, in order to help to implement more detailed seismic analysis, namely pushover, of CLT constructions. | por |
| dc.description.sponsorship | The authors thank Stora Enso Wood Products and Simpson Strong Tie for their contribution with all materials used, and to the technicians of the Structures Laboratory of the Civil Engineering Department at University of Minho for the time and dedication given during this experimental program | por |
| dc.distribution | international | por |
| dc.identifier.doi | 10.1016/j.engstruct.2019.109806 | por |
| dc.identifier.eissn | 1873-7323 | por |
| dc.identifier.issn | 0141-0296 | por |
| dc.identifier.uri | https://hdl.handle.net/1822/64964 | |
| dc.language.iso | eng | por |
| dc.peerreviewed | yes | por |
| dc.publisher | Elsevier | por |
| dc.relation | SISMO 2.0 - Stora Enso | por |
| dc.relation.publisherversion | https://www.sciencedirect.com/science/article/pii/S0141029619312957?via%3Dihub#! | por |
| dc.rights | openAccess | por |
| dc.subject | CLT building | por |
| dc.subject | Quasi-static tests | por |
| dc.subject | Pushover analysis | por |
| dc.subject | Shear walls | por |
| dc.subject | Cross Laminated Timber | por |
| dc.subject | Full-scale tests | por |
| dc.subject.fos | Engenharia e Tecnologia::Engenharia Civil | por |
| dc.subject.wos | Science & Technology | por |
| dc.title | Quasi-static tests on a two-story CLT building | por |
| dc.type | article | |
| dspace.entity.type | Publication | en |
| oaire.citationVolume | 221 | por |
| sdum.journal | Engineering Structures | por |
Ficheiros
Pacote original
1 - 1 de 1
A carregar...
- Nome:
- Quasi-static tests on a two-story CLT building_manuscript.pdf
- Tamanho:
- 1.93 MB
- Formato:
- Adobe Portable Document Format
- Descrição:
- manuscript