A tunable Fabry-Perot optical filter for application in biochemical analysis of human’s fluids

dc.contributor.authorPinheiro, C.
dc.contributor.authorRocha, J. G.
dc.contributor.authorGonçalves, L. M.
dc.contributor.authorLanceros-Méndez, S.
dc.contributor.authorMinas, Graça
dc.date.accessioned2006-09-15T16:05:56Z
dc.date.available2006-09-15T16:05:56Z
dc.date.issued2006-07
dc.description.abstractThis paper reports a Fabry-Perot tunable optical filter for application in clinical analysis, especially to measure the concentration of biochemical substances in biological fluids. Its tunable characteristics enable the measurement of different biochemical substances with the same device. It is composed of two parallel thin silver mirrors with a β-PVDF (Poly(Vinylidene Fluoride) in its β phase) film in-between as the resonance cavity. The filter is tuned by adjusting the space between the mirrors through an electric voltage inducing dipolar orientation in the β-PVDF film. Once the thickness changes of the β-PVDF film is due to variations at a molecular level, the changes are rather homogeneous within the samples. As a result, this approach achieves parallelism between the two mirrors, which is a complex problem to solve in conventional Fabry-Perot optical filters. Moreover, compared with an array of non-tunable optical filters with different cavity lengths, usually used to solve the parallelism problem, this device has a reduced area, its fabrication process is easier and it covers a wider spectral range. In addition, when used as a part of a biological fluids analysis system, it avoids the need for expensive optics and enables low-cost and portable devices, which would improve the use of spectrophotometric analysis in clinical diagnostics.eng
dc.description.sponsorshipSupport for this research was provided by the Engineering School of University of Minho (program IN2TEC), the R&D Centre Algoritmi of University of Minho and the Foundation for Science and Technology (Grant POCI/CTM/59425/2004).por
dc.distributioninternationaleng
dc.identifier.citationPinheiro, C., Rocha, J., Goncalves, L., Lanceros-Mendez, S., & Minas, G. (2006, July). A Tunable Fabry-Perot Optical Filter for Application in Biochemical Analysis of Human's Fluids. 2006 IEEE International Symposium on Industrial Electronics. IEEE. http://doi.org/10.1109/isie.2006.296054eng
dc.identifier.doi10.1109/ISIE.2006.296054por
dc.identifier.isbn9781424404964
dc.identifier.urihttps://hdl.handle.net/1822/5560
dc.language.isoengeng
dc.peerreviewedyeseng
dc.publisherIEEEeng
dc.relationinfo:eu-repo/grantAgreement/FCT/POCI/POCI%2FCTM%2F59425%2F2004/PT
dc.rightsopenAccesseng
dc.subjectFabry-Peroteng
dc.subjectOptical filtereng
dc.subjectBiochemical analysiseng
dc.subjectPVDFeng
dc.subject.wosScience & Technologypor
dc.titleA tunable Fabry-Perot optical filter for application in biochemical analysis of human’s fluidseng
dc.typeconferencePapereng
dspace.entity.typePublicationen
oaire.citationEndPage+por
oaire.citationStartPage2778por
sdum.bookTitle2006 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-7por

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
A Tunable Fabry-Perot Optical Filter for Application ISIE06.pdf
Tamanho:
444.27 KB
Formato:
Adobe Portable Document Format