Produção de um sistema sanduíche multifuncional para combater infeções em feridas crónicas

Production of multifunctional sandwich-like system for fighting infections in chronic wounds
dc.contributor.advisorFelgueiras, Helena Pradopor
dc.contributor.advisorSilva, C.por
dc.contributor.authorRibeiro, Lara Cristina Silvapor
dc.date.accessioned2025-05-29T10:45:56Z
dc.date.available2025-05-29T10:45:56Z
dc.date.issued2023-12-26
dc.date.submitted2023-10
dc.description.abstractAs feridas crónicas são caracterizadas pela interrupção do processo de cicatrização em uma ou mais fases. Estas feridas caracterizam-se por: matrizes celulares defeituosas, alta concentração microbiana, humidade desregulada, e por ficarem retidas numa fase de inflamação descoordenada, o que as deixa mais suscetíveis à presença e desenvolvimento de infeções. A estratégia geralmente adotada para gerir ou tratar estas feridas é baseia-se na aplicação de pensos. No entanto, pensos convencionais são incapazes de combater infeções, manter uma humidade local ótima, ou promover as fases de cicatrização. Assim, foi proposto desenvolver um sistema multifuncional em sanduíche, modificado com agentes bioativos, capaz de combater infeções em feridas crónicas. O sistema foi idealizado com três camadas: a camada exterior composta por um filme fibroso de policaprolactona (PCL) que trabalha como uma barreira para prevenir outros microrganismos e impurezas de alcançar à ferida; a camada intermédia formada por um hidrogel de alginato de sódio (SA) carregado com ampicilina (Amp) que mantém um ambiente húmido, absorve exsudatos e liberta a carga antimicrobiana de forma controlada; e a camada interna, também ela composta por um filme fibroso obtido da combinação de PCL e polietileno glicol (PEG), que facilita a integração e reconhecimento celulares, impede a adesão local do penso, e promove efeitos antimicrobianos complementares. Análises antimicrobianas da Amp e PEG foram realizadas contra as bactérias prevalentes em feridas crónicas, Staphylococcus aureus e Escherichia coli. O PCL foi utilizado sozinho (camada externa), ou combinado com PEG (camada interna) à concentração mínima bactericida (MBC), e processado na forma de filmes fibrosos por eletrofiação. O hidrogel foi obtido usando uma solução aquosa de SA modificada com Amp a 100×MBC. Análises termo gravimétricas determinaram a estabilidade térmica dos polímeros. O sistema demonstrou capacidade de hidratação até 60% do seu peso inicial após 24 h e o teste de degradação reportou perdas de massa de cerca de 70% após 7 dias de incubação (perfil biodegradável). A libertação do antibiótico foi monitorizada até 24 h, confirmando a libertação cadenciada das moléculas encapsuladas no hidrogel. Testes antimicrobianos determinaram a elevada eficácia do sistema (> 99% eliminação das bactérias). Ensaios de adesão confirmaram a facilidade do sistema em ser destacado sem grande esforço mecânico. Em suma, os dados mostram a eficiência do sistema sanduíche para a potencial aplicação no tratamento de feridas crónicas.por
dc.description.abstractChronic wounds are wounds in which the healing cascade gets interrupted in one or more phases. Usually, these wounds are characterized by defective cell matrices, high microbial concentration, dysregulated moisture, and for being trapped in an uncoordinated and self-sustaining inflammatory phase, which makes them more susceptible to the presence of infections. The strategy adopted to manage or treat these wounds is through the application of dressings. However, conventional dressings are not ideal, since they are incapable of fighting infections, maintaining optimum humidity at site or promoting the healing phases. As such, a multifunctional sandwich-like system was here proposed and examined for its potential in fighting CW infections. The scaffolding system was made of three layers: (outer) fibrous mat of polycaprolactone (PCL) working as a barrier for preventing other microorganisms and impurities from reaching the wound bed; (middle) sodium alginate (SA) hydrogel loaded with the antimicrobial agent ampicillin (Amp) for maintaining a moisture environment, absorbing exudates and liberating the antimicrobial payload in a paced manner; and (inner) a second fibrous mat composed of PCL and polyethylene glycol (PEG) for facilitated cell integration and recognition, preventing wound adhesion and for complementary antimicrobial effects. Antimicrobial examinations of Ampicillin and PEG were conducted against the most prevalent bacteria in CW, Staphylococcus aureus and Escherichia coli. PCL was used alone (outer layer) or modified with PEG (inner layer) at MBC and processed in the form of fibrous mats via electrospinning. The hydrogel was obtained by solvent casting-phase inversion method using SA aqueous solution in combination with Amp at 100×MBC. Thermal gravimetry and calorimetry analyses established the polymers’ thermal stability. Hydration capacity was averaged at > 60% of the sample’s weight, and degradation experiments reported a loss in mass of ≈ 70% after 7 days of incubation (biodegradable profile). Controlled release of the antibiotic was examined up to 24 h, revealing a paced liberation of the hydrogel-entrapped molecules. Antimicrobial testing determined the high efficiency of the scaffold (> 99% elimination of both bacteria). Adhesion experiments determined the scaffold’s ability to be detached without great mechanical effort. Overall, data reports the effectiveness of this sandwich-like system for potential applications in CW care.por
dc.identifier.tid203906055por
dc.identifier.urihttps://hdl.handle.net/1822/95828
dc.language.isoporpor
dc.rightsopenAccesspor
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/por
dc.subjectFilmes poliméricos fibrosospor
dc.subjectHidrogel carregado com fármacopor
dc.subjectSistema sanduíchepor
dc.subjectAnti-adesivopor
dc.subjectPotencial tratamento para feridaspor
dc.subjectFibrous polymer filmspor
dc.subjectDrug-loaded hydrogelpor
dc.subjectSandwich-like systempor
dc.subjectAnti-adhesivepor
dc.subjectEffective wound carepor
dc.subject.fosEngenharia e Tecnologiapor
dc.titleProdução de um sistema sanduíche multifuncional para combater infeções em feridas crónicaspor
dc.title.alternativeProduction of multifunctional sandwich-like system for fighting infections in chronic woundspor
dc.typemasterThesiseng
dspace.entity.typePublicationen
sdum.degree.grade17 valorespor
sdum.uoeiEscola de Engenhariapor
thesis.degree.grantorUniversidade do Minhopor
thesis.degree.nameMestrado em Engenharia Química e Biológicapor

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
Lara Cristina Silva Ribeiro.pdf
Tamanho:
2.39 MB
Formato:
Adobe Portable Document Format
Descrição:
Dissertação de mestrado