Patient-specific outcome simulation after surgical correction of Pectus Excavatum: a preliminary study

dc.contributor.authorCouto, Mafalda Araújo Searapor
dc.contributor.authorFonseca, João Luís Gomespor
dc.contributor.authorMoreira, António Herculano Jesuspor
dc.contributor.authorHenriques-Coelho, Tiagopor
dc.contributor.authorFonseca, Jaime C.por
dc.contributor.authorPinho, A. C. Marquespor
dc.contributor.authorCorreia-Pinto, Jorgepor
dc.contributor.authorVilaça, João L.por
dc.date.accessioned2021-04-01T12:47:53Z
dc.date.available2021-04-01T12:47:53Z
dc.date.issued2019
dc.date.updated2021-03-31T21:59:36Z
dc.description.abstractAlthough minimally invasive Nuss procedure is frequently performed to correct Pectus Excavatum, the successful aesthetical outcome is not always ensured. Using the computed tomography (CT) data of six patients, high-quality surfaces of the anterior chest wall were generated, alongside with a personalized corrective-bar. Through finite element method (FEM), replicating the surgical procedure, a simulation of the anterior chest wall correction was conducted. The assessment of this methodology was verified by comparing the metrics from the real meshes (3D scanned before and after surgery) and simulated meshes (obtained before and after FEM). Results show a mean difference of 2.85 +/- 5.77 mm on the point of maximum correction between simulated and real outcomes. No statistical differences were found (p = 0.281). High aesthetical similarity was observed concerning simulated and real outcomes. The proposed methodology presents a patient-specific simulation that may be used to plan, predict and improve the surgical outcome of the Nuss procedure. Further studies should continue to improve the presented methodology.por
dc.description.sponsorshipThis work has been funded by FEDER funds, through the Competitiveness Factors Operational Programme (COMPETE), and by National funds, through the Foundation for Science and Technology (FCT), under the scope of the projects POCI-01-0145-FEDER-007038; NORTE-01-0145-FEDER-000013; and NORTE-01-0145-FEDER-024300, supported by the Northern Portugal Regional Operational Programme (NORTE 2020), under the Portugal 2020 Partnership Agreement, through the European Regional Development Fund (FEDER). Joao Gomes-Fonseca was funded by FCT under the Ph.D. grant PD/BDE/113597/2015.por
dc.distributioninternationalpor
dc.identifier.doi10.1117/12.2512773por
dc.identifier.isbn9781510625471por
dc.identifier.issn0277-786X
dc.identifier.urihttps://hdl.handle.net/1822/71190
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherSociety of Photo-optical Instrumentation Engineers (SPIE)por
dc.relationPOCI-01-0145-FEDER-007038por
dc.relationNORTE-01-0145-FEDER-000013por
dc.relationNORTE-01-0145-FEDER-024300por
dc.relationPD/BDE/113597/2015por
dc.relation.publisherversionhttps://www.spiedigitallibrary.org/conference-proceedings-of-spie/10950/109504I/Patient-specific-outcome-simulation-after-surgical-correction-of-Pectus-Excavatum/10.1117/12.2512773.shortpor
dc.rightsopenAccesspor
dc.subjectAesthetic outcome predictionpor
dc.subjectFinite element methodpor
dc.subjectPectus excavatumpor
dc.subjectSurgical simulationpor
dc.subject.wosScience & Technology
dc.titlePatient-specific outcome simulation after surgical correction of Pectus Excavatum: a preliminary studypor
dc.typeconferencePaperpor
dspace.entity.typePublicationen
oaire.citationConferenceDate16 - 21 Febr. 2019por
oaire.citationConferencePlaceSan Diego, California, United Statespor
oaire.citationVolume10950
sdum.bookTitleMEDICAL IMAGING 2019: COMPUTER-AIDED DIAGNOSIS
sdum.conferencePublicationMedical Imaging 2019: Computer-Aided Diagnosispor
sdum.event.titleSPIE Medical Imaging 2019por
sdum.event.typeconferencepor
sdum.export.identifier10284
sdum.journalProceedings of SPIE

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
Patient_specific.pdf
Tamanho:
591.66 KB
Formato:
Adobe Portable Document Format