Peripheral myopization and visual performance with experimental rigid gas permeable and soft contact lens design
| dc.contributor.author | Pauné, Jaume | por |
| dc.contributor.author | Queirós, A. | por |
| dc.contributor.author | Quevedo, L. | por |
| dc.contributor.author | Neves, Helena | por |
| dc.contributor.author | Ferreira, Daniela Lopes | por |
| dc.contributor.author | González-Méijome, José Manuel | por |
| dc.date.accessioned | 2014-10-09T15:25:32Z | |
| dc.date.available | 2014-10-09T15:25:32Z | |
| dc.date.issued | 2014 | |
| dc.date.updated | 2014-09-18T08:54:26Z | |
| dc.description | "Article in press". Available online 11 September 2014 | por |
| dc.description.abstract | Purpose: To evaluate the performance of two experimental contact lenses (CL) designed to induce relativeperipheral myopic defocus in myopic eyes.Methods: Ten right eyes of 10 subjects were fitted with three different CL: a soft experimental lens (Exp-SCL), a rigid gas permeable experimental lens (ExpRGP) and a standard RGP lens made of the same material(StdRGP). Central and peripheral refraction was measured using a Grand Seiko open-field autorefrac-tometer across the central 60◦of the horizontal visual field. Ocular aberrations were measured with aHartman-Shack aberrometer, and monocular contrast sensitivity function (CSF) was measured with aVCTS6500 without and with the three contact lenses.Results: Both experimental lenses were able to increase significantly the relative peripheral myopic defo-cus up to −0.50 D in the nasal field and −1.00 D in the temporal field (p < 0.05). The ExpRGP induceda significantly higher myopic defocus in the temporal field compared to the ExpSCL. ExpSCL inducedsignificantly lower levels of Spherical-like HOA than ExpRGP for the 5 mm pupil size (p < 0.05). Both exper-imental lenses kept CSF within normal limits without any statistically significant change from baseline(p > 0.05).Conclusions: RGP lens design seems to be more effective to induce a significant myopic change in therelative peripheral refractive error. Both lenses preserve a good visual performance. The worsened opticalquality observed in ExpRGP was due to an increased coma-like and spherical-like HOA. However, noimpact on the visual quality as measured by CSF was observed. | por |
| dc.description.sponsorship | Paunevision (Spain) sponsored the present study. This work was also funded in part by FEDER (COMPETE Program) in the framework of projects PTDC/SAU-BEB/098391/2008, PTDC/SAUBEB/098392/2008 and Strategic Project PEST-C/FIS/UI607/2011 granted throught the Portuguese Foundation for Science and Technology (FCT). | por |
| dc.distribution | international | por |
| dc.identifier.doi | 10.1016/j.clae.2014.08.001 | por |
| dc.identifier.issn | 1367-0484 | por |
| dc.identifier.pmid | 25217826 | por |
| dc.identifier.uri | https://hdl.handle.net/1822/30459 | |
| dc.language.iso | eng | por |
| dc.peerreviewed | yes | por |
| dc.publisher | Elsevier | por |
| dc.relation | info:eu-repo/grantAgreement/FCT/5876-PPCDTI/98391/PT | |
| dc.rights | openAccess | por |
| dc.subject | Myopia | por |
| dc.subject | Custom-design | por |
| dc.subject | Contact lenses | por |
| dc.subject | Peripheral refraction | por |
| dc.subject.wos | Science & Technology | por |
| dc.title | Peripheral myopization and visual performance with experimental rigid gas permeable and soft contact lens design | por |
| dc.type | article | |
| dspace.entity.type | Publication | en |
| oaire.citationEndPage | 6 | por |
| oaire.citationIssue | 6 | por |
| oaire.citationStartPage | 1 | por |
| oaire.citationTitle | Contact lens and anterior eye | por |
| oaire.citationVolume | 37 | por |
| sdum.journal | Contact lens and anterior eye | por |
| sdum.publicationstatus | published | por |
Ficheiros
Pacote original
1 - 1 de 1
A carregar...
- Nome:
- Paune_2014_CLAE (Peripheral myopization and visual performance with experimental RPG and LCM).pdf
- Tamanho:
- 947.31 KB
- Formato: