Biomechanical behaviour of cancellous bone on patellofemoral arthroplasty with journey prosthesis : a finite element study

dc.contributor.authorCastro, Andrépor
dc.contributor.authorCompleto, Antóniopor
dc.contributor.authorSimões, José A.por
dc.contributor.authorFlores, Paulopor
dc.date.accessioned2015-01-06T11:16:49Z
dc.date.available2015-01-06T11:16:49Z
dc.date.issued2015
dc.date.submitted2015
dc.description.abstractIsolated patellofemoral (PF) arthritis of the knee is a common cause of anterior knee pain and disability. Patellofemoral arthroplasty (PFA) is a bone conserving solution for patients with PF degeneration. Failure mechanisms of PFA include growing tibiofemoral arthritis and loosening of components. The implant loosening can be associated with bone resorption, or fatigue-failure of bone by overload. This research work aims at determining the structural effects of the implantation of PF prosthesis Journey PFJ (Smith&Nephew, USA) on femur cancellous bone. For this purpose, the finite element (FE) method is considered to perform computational simulations for different conditions, such as well-fixed and loosening scenarios. From the global results obtained, in the well-fixed scenario, a strain decrease on cancellous bone was noticed, which can be related to bone resorption. In the loosening scenario, when the cement layer becomes inefficient, a significant increase of cancellous bone strain was observed, which can be associated with bone fatigue-failure. These strain changes suggest a weakness of the femur after PFA.por
dc.description.sponsorshipFundação para a Ciência e a Tecnologia (FCT)por
dc.distributioninternationalpor
dc.identifier.doi10.1080/10255842.2013.870999por
dc.identifier.issn1025-5842por
dc.identifier.issn1476-8259por
dc.identifier.urihttps://hdl.handle.net/1822/32371
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherTaylor and Francispor
dc.rightsopenAccesspor
dc.subjectKneepor
dc.subjectCancellous bonepor
dc.subjectFinite element methodpor
dc.subjectPatellofemoral arthroplastypor
dc.subject.fosEngenharia e Tecnologia::Engenharia dos Materiaispor
dc.subject.wosScience & Technologypor
dc.titleBiomechanical behaviour of cancellous bone on patellofemoral arthroplasty with journey prosthesis : a finite element studypor
dc.typearticlepor
dspace.entity.typePublicationen
oaire.citationEndPage1098por
oaire.citationIssue10por
oaire.citationStartPage1090por
oaire.citationTitleComputer Methods in Biomechanics and Biomedical Engineeringpor
oaire.citationVolume18por
sdum.journalComputer Methods in Biomechanics and Biomedical Engineeringpor
sdum.publicationstatuspublishedpor

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
6.7.47 2015.pdf
Tamanho:
1.17 MB
Formato:
Adobe Portable Document Format
Descrição:
Documento principal