Electro-responsive silk fibroin microneedles for controlled release of insulin

dc.commentshttp://3bs.uminho.pt/node/21158por
dc.contributor.authorQi, Zhenzhenpor
dc.contributor.authorTao, Xiaoshengpor
dc.contributor.authorTan, Guohongfangpor
dc.contributor.authorTian, Binpor
dc.contributor.authorZhang, Lehaopor
dc.contributor.authorKundu, Subhas Cpor
dc.contributor.authorLu, Shenzhoupor
dc.date.accessioned2024-05-14T13:52:56Z
dc.date.embargo10000-01-01
dc.date.issued2023
dc.date.updated2024-04-23T15:53:26Z
dc.descriptionAvailable online 4 May 2023por
dc.description.abstractTo date, very limited work has been done on convenient and active control of insulin release. Herein, we report an electro-responsive insulin delivery system based on thiolated silk fibroin. The disulfide cross-linking points in TSF were reduced and broken to form sulfhydryl groups under electrification, which led to the increase of microneedle swelling degree and promoted insulin release. After power failure, the sulfhydryl group is oxidised to form disulfide bond crosslinking point again, resulting in the reduction of microneedle swelling degree and thus the reduction of release rate. The insulin loaded in the electro-responsive insulin delivery system showed good reversible electroresponsive release performance. The addition of graphene reduced the microneedle resistance and increased the drug release rate under current conditions. In vivo studies on type 1 diabetic mice show that electro-responsive insulin delivery system effectively controls the blood glucose before and after feeding by switching on and off the power supply, and this blood glucose control can be maintained within the safe range (100–200 mg/dL) for a long time (11h). Such electrically responsive delivery microneedles show potential for integration with glucose signal monitoring and are expected to build closed-loop insulin delivery systems.por
dc.description.sponsorshipNational Natural Science Foundation of China (Grant No. 51973144), Natural Science Research of Jiangsu Higher Education Institutions of China (Grant No. 20KJA540002), PAPD and Six Talent Peaks Project in Jiangsu Province (Grant No. SWYY-038) supported thiswork.por
dc.distributioninternationalpor
dc.identifier.articlenumber124684por
dc.identifier.citationQi Z., Tao X., Tan G., Tian B., Zhang L., Kundu S. C., Lu S. Electro-responsive silk fibroin microneedles for controlled release of insulin, International Journal of Biological Macromolecules, Vol. 242, Issue 1, pp. 124684, doi:10.1016/j.ijbiomac.2023.124684, 2023por
dc.identifier.doi10.1016/j.ijbiomac.2023.124684por
dc.identifier.eissn1879-0003por
dc.identifier.issn0141-8130por
dc.identifier.pmid37148951por
dc.identifier.urihttps://hdl.handle.net/1822/91351
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherElsevierpor
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S0141813023015787por
dc.rightsrestrictedAccesspor
dc.subjectElectro-responsivepor
dc.subjectInsulinpor
dc.subjectMicroneedlespor
dc.subjectSilk Fibroinpor
dc.titleElectro-responsive silk fibroin microneedles for controlled release of insulinpor
dc.typearticle
dspace.entity.typePublicationen
oaire.citationEndPage13por
oaire.citationStartPage1por
oaire.citationVolume242por
sdum.journalInternational Journal of Biological Macromoleculespor

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
21158-1-s20-s0141813023015787-main.pdf
Tamanho:
11.62 MB
Formato:
Adobe Portable Document Format