Radiated EMC immunity investigation of common recognition identification platform for medical applications

dc.contributor.authorMiranda, Jorge Miguel Pereira Coutadapor
dc.contributor.authorCabral, Jorgepor
dc.contributor.authorRavelo, Blaisepor
dc.contributor.authorWagner, Stefanpor
dc.contributor.authorPedersen, Christian F.por
dc.contributor.authorMemon, Mukhtiarpor
dc.contributor.authorMathiesen, Mortenpor
dc.date.accessioned2018-03-19T15:35:39Z
dc.date.issued2015
dc.date.updated2018-03-05T11:45:57Z
dc.description.abstractAn innovative e-healthcare platform named common recognition and identification platform (CRIP) was developed and tested as part of the CareStore project. CareStore and CRIP aims at delivering accurate and safe disease management by minimising human operator errors in hospitals and care facilities. To support this, the CRIP platform features fingerprint biometrics and near field communication (NFC) for user identification; and Bluetooth communication support for a range of telemedicine medical devices adhering to the IEEE 11073 standard. The aim of this study was to evaluate the electromagnetic compatibility (EMC) immunity of the CRIP platform in order to validate it for medical application use. The first prototype of CRIP was demonstrated to operate as expected by showing the user identification function feasibility, both via NFC and biometric, and by detection of Bluetooth devices via radio frequency (RF) scanning. The NFC module works in the 13.56 MHz band and the Bluetooth module work in the 2.4 GHz band, according to the IEEE 802.15.1 standard. The standard test qualification of the CRIP was performed based on the radiated EMC immunity with respect to the EN 61000-4-3 standard. The immunity tests were conducted under industrial EMC compliance with electric field aggression, with levels up to 10 V/m in both horizontal and vertical polarisations when the test antenna and the CRIP were placed at a distance of 3 m. It was found that the CRIP device complies with the European electromagnetic (EM) radiation immunity requirements.por
dc.description.publicationversioninfo:eu-repo/semantics/publishedVersionpor
dc.description.sponsorshipThis research work was supported by European Framework Program FP7 Research for the Benefit of Small and Medium Enterprises (SMEs), project FP7-SME-2012- 315158-CareStore.por
dc.distributioninternational
dc.identifier.doi10.1051/epjap/2014140230por
dc.identifier.issn1286-0042
dc.identifier.urihttps://hdl.handle.net/1822/52834
dc.language.isoengpor
dc.peerreviewedyes
dc.publisherEDP Sciencespor
dc.relationinfo:eu-repo/grantAgreement/EC/FP7/315158/EUpor
dc.rightsrestrictedAccesspor
dc.subject.wosScience & Technology
dc.titleRadiated EMC immunity investigation of common recognition identification platform for medical applicationspor
dc.typearticlepor
dspace.entity.typePublicationen
oaire.citationIssue1por
oaire.citationVolume69
sdum.export.identifier4179
sdum.journalEuropean Physical Journal: Applied Physics

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
2015 - Radiated EMC immunity investigation of common recognition identification platform for medical applications.pdf
Tamanho:
989.7 KB
Formato:
Adobe Portable Document Format