Design parameters for seismically retrofitted masonry-to-timber connections: injection anchors

dc.contributor.authorMoreira, Susanapor
dc.contributor.authorRamos, Luís F.por
dc.contributor.authorOliveira, Daniel V.por
dc.contributor.authorLourenço, Paulo B.por
dc.date.accessioned2017-03-07T15:15:03Z
dc.date.available2017-03-07T15:15:03Z
dc.date.issued2016
dc.description.abstractProper structural connections play an important role in ensuring seismic loads distribution and developing global damage mechanisms of structures. In historical unreinforced masonry buildings, effective connections between masonry walls and timber floors or walls through the use of anchors can prevent the occurrence of out-of-plane mechanisms and promote box-like behavior. Particularly for historic structures, injection anchors can comply with requirements as decreased architectural impact and minimum intervention. Therefore, this paper aims at developing structural design parameters and recommendations that allow the design of connections retrofitted with injection anchors, found in historical unreinforced masonry buildings, built during the 19th century, in Portugal. Existing strength prediction formulae based on behavior models, and idealized force-displacement curves were developed to better fit the results obtained from a series of quasi-static monotonic and cyclic pullout tests carried out on pairs of injection anchors. Behavior models were able to approximate the experimental results, if adapted to the specificities of historical masonry. Further validation is needed, particularly for the combined cone-bond model. From the idealized curves, displacement acceptance criteria, expected forces, and behavior factors were proposed, according to the performance-based approaches recommended by EC8-Part 3 and ASCE/SEI 41-13. Finally, retrofit design recommendations were addressed.por
dc.description.sponsorshipThis work was partially funded by project FP7-ENV-2009-1-244123-NIKER of the 7th Framework Program of the European Commission, which is gratefully acknowledged. Authors would like to thank the technical staff of the Structures Lab. of University of Minho for the assistance provided preparing and carrying out the tests and also, Monumenta, Ltd. for the construction of the specimens and Cintec® for the installation of the injection anchors.por
dc.distributioninternationalpor
dc.identifier.citationMoreira, S., Ramos, L. F., Oliveira, D. V., & Lourenco, P. B. (2016). Design Parameters for Seismically Retrofitted Masonry-to-Timber Connections: Injection Anchors. International Journal of Architectural Heritage, 10(2-3), 217-234. doi: 10.1080/15583058.2015.1113339por
dc.identifier.doi10.1080/15583058.2015.1113339por
dc.identifier.eissn1558-3066por
dc.identifier.issn1558-3058por
dc.identifier.urihttps://hdl.handle.net/1822/44922
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherTaylor and Francispor
dc.relationinfo:eu-repo/grantAgreement/EC/FP7/244123/EUpor
dc.rightsopenAccesspor
dc.subjectMasonry-to-timberpor
dc.subjectConnectionspor
dc.subjectInjection anchorspor
dc.subjectSeismic retrofitpor
dc.subjectDesignpor
dc.subjectIdealized curvepor
dc.subjectPerformance criteriapor
dc.subjectCyclic pullout testpor
dc.subject.fosEngenharia e Tecnologia::Engenharia Civilpor
dc.subject.wosArts & Humanitiespor
dc.subject.wosScience & Technologypor
dc.titleDesign parameters for seismically retrofitted masonry-to-timber connections: injection anchorspor
dc.typearticle
dspace.entity.typePublicationen
oaire.citationEndPage234por
oaire.citationIssue2-3por
oaire.citationStartPage217por
oaire.citationTitleInternational Journal of Architectural Heritagepor
oaire.citationVolume10por
sdum.journalInternational Journal of Architectural Heritagepor
sdum.publicationstatusinfo:eu-repo/semantics/publishedVersionpor