Finite element analysis of stress extent at peri-implant bone surrounding external hexagon or Morse taper implants

dc.contributor.authorMacedo, J. P.por
dc.contributor.authorPereira, J.por
dc.contributor.authorFaria, J.por
dc.contributor.authorPereira, C. A.por
dc.contributor.authorAlves, J. L.por
dc.contributor.authorHenriques, B.por
dc.contributor.authorSouza, J. C. M.por
dc.contributor.authorLópez-López, J.por
dc.date.accessioned2018-03-23T13:53:59Z
dc.date.available2018-03-23T13:53:59Z
dc.date.issued2017-07
dc.description.abstractThe purpose of the present study was to evaluate the distribution of stresses and consequent bone volume affected surrounding external hexagon or Morse taper dental implant systems by finite element analysis.por
dc.description.publicationversioninfo:eu-repo/semantics/publishedVersionpor
dc.description.sponsorshipThe authors acknowledge the support provided by the Dept. of Mechanical Engineering at the University of Minho (Portugal) and by Drawing 3D implicit Finite Element Code (DD3imp, Portugal). This study was supported by FCT-Portugal (EXCL/EMS-TEC/0460/2012; UID/EEA/04436/2013, NORTE-01-0145-FEDER-000018 - HAMaBICo), CNPq-Brazil (PVE/CAPES/CNPq/407035/2013-3).por
dc.distributioninternationalpor
dc.identifier.doi10.1016/j.jmbbm.2017.03.011por
dc.identifier.issn1751-6161por
dc.identifier.pmid28499606por
dc.identifier.urihttps://hdl.handle.net/1822/53334
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherElsevier Sciencepor
dc.rightsopenAccesspor
dc.subjectBiomechanical Phenomenapor
dc.subjectCancellous Bonepor
dc.subjectCortical Bonepor
dc.subjectFinite Element Analysispor
dc.subjectHumanspor
dc.subjectMandiblepor
dc.subjectStress, Mechanicalpor
dc.subjectDental Implantspor
dc.subjectDental Stress Analysispor
dc.subjectBone resorptionpor
dc.subjectImplant designpor
dc.subjectMarginal bone losspor
dc.subjectMorse taper implantpor
dc.subjectFEApor
dc.subjectdental implantpor
dc.subject.fosEngenharia e Tecnologia::Engenharia Mecânicapor
dc.subject.wosScience & Technologypor
dc.titleFinite element analysis of stress extent at peri-implant bone surrounding external hexagon or Morse taper implantspor
dc.typearticlepor
dspace.entity.typePublicationen
oaire.citationEndPage447por
oaire.citationStartPage441por
oaire.citationVolume71por
sdum.journalJournal of the Mechanical Behavior of Biomedical Materialspor

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
art20.pdf
Tamanho:
1006.56 KB
Formato:
Adobe Portable Document Format