Validation of respirometry as a short-term method to assess the efficacy of biocides

dc.contributor.authorSimões, M.
dc.contributor.authorPereira, Maria Olívia
dc.contributor.authorVieira, M. J.
dc.date.accessioned2005-10-31T14:03:23Z
dc.date.available2005-10-31T14:03:23Z
dc.date.issued2005
dc.description.abstractThis study shows that a short-term respirometric measurement based on the rate of oxygen uptake needed to oxidize glucose is a reliable and fast method to assess biocide efficacy against P. fluorescens cells. Respiratory activity using oxygen consumption rate, the determination of viable and nonviable cells using Live/Dead® BacLightTM kit and colony formation units (CFU), were compared as indicators of the biocidal efficacy of ortho-phthalaldehyde (OPA). The results showed tha determining the effect of OPA against P. fluorescens using the different methods leads to different conclusions. The minimum bactericidal concentration (MBC) was 80 mg l-¹, 100 mg l-¹ and 65 mg l-¹ respectively, using respiratory activity, viability using BacLight counts and culturability. The plate count method was shown to underestimate the biocidal action of OPA, whilst data from respirometry and viability using Live/Dead BacLight kit correlated strongly and were not statistically different when yellow cells were considered nonviable. Respirometry therefore represents an expeditious, non-destructive and accurate method to determine the antimicrobial action of biocides against aerobic heterotrophic bacteria.eng
dc.description.sponsorshipFundação para a Ciência e a Tecnologia (FCT)por
dc.distributioninternationaleng
dc.identifier.citation"Biofouling : The journal of bioadhesion and biofilm research". ISSN 0892-7014. 21:1 (2005) 9-17.eng
dc.identifier.doi10.1080/08927010500066982por
dc.identifier.issn0892-7014eng
dc.identifier.pmid16019387por
dc.identifier.urihttps://hdl.handle.net/1822/3375
dc.language.isoengeng
dc.peerreviewedyeseng
dc.publisherTaylor and Franciseng
dc.relation.publisherversionhttp://journalsonline.tandf.co.uk/eng
dc.rightsopenAccesseng
dc.subjectRespiratory activityeng
dc.subjectLive/Dead BacLightTMeng
dc.subjectCulturabilityeng
dc.subjectViabilityeng
dc.subjectDisinfectioneng
dc.subjectBiocideeng
dc.subjectLive/Dead BacLight™por
dc.subject.wosScience & Technologypor
dc.titleValidation of respirometry as a short-term method to assess the efficacy of biocideseng
dc.typearticlepor
dspace.entity.typePublicationen
oaire.citationEndPage17por
oaire.citationIssue1por
oaire.citationStartPage9por
oaire.citationVolume21por
sdum.journalBiofoulingpor
sdum.number1eng
sdum.pagination9-17eng
sdum.publicationstatuspublishedeng
sdum.volume21eng

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
Biofouling2005-Simoes[2].pdf
Tamanho:
722.06 KB
Formato:
Adobe Portable Document Format