Multiphoton microscopy for label-free colorectal cancer diagnosis: towards an endoscopic application
| dc.comments | EE/2026/4520 | |
| dc.contributor.advisor | Correia, J. H. | |
| dc.contributor.advisor | Maciel, Marino Jesus Correia | |
| dc.contributor.author | Freitas, Ruben Brandão | |
| dc.date.accessioned | 2026-09-23T13:19:55Z | |
| dc.date.embargo | 2027-07-06 | |
| dc.date.issued | 2026-07-06 | |
| dc.date.submitted | 2026-08 | |
| dc.description.abstract | O cancro colorretal (CRC) mantém-se como uma das principais causas de mortalidade associada ao cancro a nível mundial, sendo que os protocolos de diagnóstico atuais dependem de procedimentos invasivos e de análises histopatológicas demoradas. Neste contexto, técnicas de imagiologia ótica capazes de caracterizar tecidos in vivo têm emergido como alternativas promissoras à biópsia convencional. Esta tese investiga o potencial da tomografia de coerência ótica (OCT) e da microscopia multifotónica (MPM) no diagnóstico do CRC, com foco na sua futura integração em sistemas endoscópicos. De forma a possibilitar estudos controlados e reprodutíveis, foram desenvolvidos modelos biológicos e fantomas. O ensaio da membrana corioalantóica (CAM) foi utilizado como plataforma in vivo para o crescimento de tecidos colorretais não malignos e malignos. Os fantomas foram usados para replicar as propriedades óticas e bioquímicas dos tecidos biológicos. No âmbito da OCT, foi implementada uma análise quantitativa baseada no coeficiente de atenuação de tecidos em modelos CAM, utilizando uma máquina de vetores de suporte (SVM) treinada com características extraídas de duas regiões a diferentes profundidades. A validação cruzada aninhada produziu um desempenho ótimo, com valores de exatidão, sensibilidade, precisão e AUC iguais a 1.0. Simultaneamente, a MPM foi explorada para imagiologia funcional através da deteção de fluoróforos endógenos (NAD(P)H e FAD), permitindo a caracterização metabólica através do rácio redox. Foram fabricados filtros óticos altamente seletivos (centrados em 485 nm e 530 nm) que permitiram uma análise metabólica fiável mesmo em fantomas complexos, revelando diferenças estatisticamente significativas entre amostras normais e tumorais (teste de Mann-Whitney U, P<0.05). Apesar destes avanços, diversos desafios, como a capacidade de deteção de sinal, foram identificados, evidenciando a necessidade de otimizações futuras. A viabilidade da miniaturização dos sistemas OCT e MPM para integração em colonoscópios foi também avaliada, delineando os principais requisitos para a sua aplicação clínica. No geral, este trabalho estabelece um enquadramento experimental e tecnológico abrangente para sistemas de imagiologia ótica integrados contribuindo para o desenvolvimento da biópsia ótica em tempo real e sem marcadores no diagnóstico do CRC. | por |
| dc.description.abstract | Colorectal cancer (CRC) remains one of the leading causes of cancer-related mortality worldwide, with current diagnostic approaches relying on invasive and time-consuming histopathological analysis. In this context, optical imaging techniques capable of in vivo tissue characterization have emerged as promising alternatives to traditional biopsy. This thesis investigates the potential of optical coherence tomography (OCT) and multiphoton microscopy (MPM) for CRC diagnosis, with a focus on their future integration into endoscopic platforms. To enable controlled and reproducible experimentation, both biological and tissue-mimicking phantoms were developed. The chorioallantoic membrane (CAM) assay served as an in vivo platform for the growth of non-malignant and malignant colorectal tissues. The phantoms were designed to replicate the optical and biochemical properties of biological samples. For OCT, a quantitative analysis based on the attenuation coefficients of tissues in CAM assays was conducted using a support vector machine (SVM) classifier trained on features extracted from two distinct depth regions. Nested cross-validation achieved optimal performance, with accuracy, recall, precision, and AUC all reaching 1.0. In parallel, MPM was investigated for functional imaging through the detection of endogenous fluorophores (reduced nicotinamide adenine dinucleotide (phosphate) (NAD(P)H) and flavin adenine dinucleotide (FAD)), enabling metabolic characterization via the redox ratio. Highly selective optical filters (centered at 485 nm and 530 nm) were fabricated, allowing reliable metabolic analysis even in complex phantoms and revealing statistically significant differences between normal and tumoral samples (Mann- Whitney U test, P <0.05). Despite these advances, several challenges, such as signal detection efficiency, were identified, highlighting the need for further optimization. The feasibility of miniaturizing OCT and MPM systems for integration into conventional colonoscopes was also assessed, outlining key requirements for clinical translation. Overall, this work establishes a comprehensive experimental and technological framework for integrated optical imaging systems, contributing toward real-time, label-free optical biopsy for CRC diagnosis. | eng |
| dc.description.sponsorship | To Fundação para a Ciência e Tecnologia (FCT), thank you for supporting my research. This work was funded under the grant reference 2021.06966.BD (https://doi.org/10.54499/2021.06966.BD) and by MPhotonBiopsy, PTDC/FISOTI/1259/2020 (https://doi.org/10.54499/PTDC/FIS-OTI/1259/2020). | |
| dc.identifier.tid | 101826400 | |
| dc.identifier.uri | https://hdl.handle.net/1822/103712 | |
| dc.language.iso | eng | |
| dc.relation | Micro-opto-electro-mechanical system based on multi-photon microscopy for integration in colonoscopy [2021.06966.BD] | |
| dc.relation | Real-time multi-photon microscopy for optical biopsy of colorectal tissues [PTDC/FIS-OTI/1259/2020] | |
| dc.rights | embargoedAccess (1 Year) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0/ | |
| dc.subject | Biópsia ótica | |
| dc.subject | Cancro colorrectal | |
| dc.subject | Fantomas de tecido colorrectal | |
| dc.subject | Microscopia multifotónica | |
| dc.subject | Tomografia de coerência óptica | |
| dc.subject | Colorectal cancer | |
| dc.subject | Colorectal tissue phantoms | |
| dc.subject | Multiphoton microscopy | |
| dc.subject | Optical biopsy | |
| dc.subject | Optical coherence tomography | |
| dc.subject.fos | Engenharia e Tecnologia::Engenharia Médica | |
| dc.title | Multiphoton microscopy for label-free colorectal cancer diagnosis: towards an endoscopic application | eng |
| dc.type | doctoralThesis | |
| dspace.entity.type | Publication | |
| oaire.awardNumber | 2021.06966.BD | |
| oaire.awardNumber | PTDC/FIS-OTI/1259/2020 | |
| oaire.awardTitle | Micro-opto-electro-mechanical system based on multi-photon microscopy for integration in colonoscopy [2021.06966.BD] | |
| oaire.awardTitle | Real-time multi-photon microscopy for optical biopsy of colorectal tissues [PTDC/FIS-OTI/1259/2020] | |
| oaire.awardURI | https://hdl.handle.net/1822/101452 | |
| oaire.awardURI | https://hdl.handle.net/1822/98679 | |
| oaire.funderIdentifier | http://doi.org/10.13039/501100001871 | |
| oaire.funderIdentifier | http://doi.org/10.13039/501100001871 | |
| oaire.funderName | Fundação para a Ciência e a Tecnologia, I.P. | |
| oaire.funderName | Fundação para a Ciência e a Tecnologia, I.P. | |
| oaire.fundingStream | Concurso para Financiamento de Projetos de Investigação Científica e Desenvolvimento Tecnológico em Todos os Domínios Científicos - 2020 | |
| relation.isProjectOfPublication | 4cea8bc3-2254-4263-b3f3-9045653c1cf4 | |
| relation.isProjectOfPublication | db9d6795-1470-4526-b033-84695c913b43 | |
| relation.isProjectOfPublication.latestForDiscovery | 4cea8bc3-2254-4263-b3f3-9045653c1cf4 | |
| sdum.degree.grade | Muito bom | |
| sdum.uoei | Escola de Engenharia | |
| thesis.degree.grantor | Universidade do Minho | por |
| thesis.degree.name | Doutoramento em Engenharia Biomédica |
Ficheiros
Pacote original
1 - 1 de 1
A carregar...
- Nome:
- Ruben Brandao Freitas.pdf
- Tamanho:
- 89.56 MB
- Formato:
- Adobe Portable Document Format