Correlation between different Scheimpflug-based lens densitometry analysis and effective phacoemulsification time in mild nuclear cataracts

dc.contributor.authorFaria-Correia, Fernandopor
dc.contributor.authorLopes, Bernardopor
dc.contributor.authorMonteiro, Tiagopor
dc.contributor.authorFranqueira, Nunopor
dc.contributor.authorAmbrósio Jr., Renatopor
dc.date.accessioned2019-01-14T11:18:09Z
dc.date.issued2018-06
dc.description.abstractTo assess the correlations between preoperative Scheimpflug-based lens densitometry and effective phacoemulsification time (EPT) in age-related nuclear cataracts.por
dc.description.abstractPurpose To assess the correlations between preoperative Scheimpflug-based lens densitometry and effective phacoemulsification time (EPT) in age-related nuclear cataracts. Design Retrospective consecutive study. Methods The setting was the Ophthalmology Department, Hospital de Braga, Portugal. The study population included 50 eyes (42 patients) with age-related nuclear cataracts submitted to uneventful phacoemulsification surgery. Different analysis methods of Scheimpflug-based lens densitometry were performed: Pentacam Nucleus Staging (PNS) score with an ordinal scale from 0 to 5 and three-dimensional (3D), linear and region of interest (ROI) methods, which are displayed on an absolute scale (from 0 to 100%). EPT was calculated for the cataract surgery, which was performed by the same surgeon. Correlations between lens densitometry variables and EPT were determined using Pearson or Spearman correlation coefficients according to data normality. Results There were significant correlations between EPT and average density and maximum density variables derived from the 3D (r = 0.596, p < 0.001; r = 0.632, p < 0.001, respectively) and ROI (r = 0.527, p < 0.001; r = 0.575, p < 0.001, respectively) methods. The average density was the only parameter derived from the linear analysis that showed a significant correlation with EPT (r = 0.293, p = 0.039). The PNS score did not show a significant correlation with EPT (rho = 0.124, p = 0.390). Conclusion The densitometric parameters based on the 3D method showed the highest correlations with EPT. The referred lens densitometric analysis approach may be used in preoperative assessment in order to predict EPT more efficiently in age-related nuclear cataractspor
dc.description.publicationversioninfo:eu-repo/semantics/publishedVersionpor
dc.distributioninternationalpor
dc.identifier.citationFaria-Correia, F., Lopes, B., Monteiro, T., Franqueira, N., & Ambrósio, R. (2018). Correlation between different Scheimpflug-based lens densitometry analysis and effective phacoemulsification time in mild nuclear cataracts. International ophthalmology, 38(3), 1103-1110por
dc.identifier.doi10.1007/s10792-017-0566-7por
dc.identifier.eissn1573-2630
dc.identifier.issn0165-5701
dc.identifier.pmid28550347por
dc.identifier.urihttps://hdl.handle.net/1822/58133
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherSpringer Verlagpor
dc.relation.publisherversionhttps://link.springer.com/article/10.1007/s10792-017-0566-7por
dc.rightsclosedAccesspor
dc.subjectAgedpor
dc.subjectAged, 80 and overpor
dc.subjectCataractpor
dc.subjectDensitometrypor
dc.subjectFemalepor
dc.subjectHumanspor
dc.subjectLens, Crystallinepor
dc.subjectMalepor
dc.subjectMiddle Agedpor
dc.subjectPhacoemulsificationpor
dc.subjectRetrospective Studiespor
dc.subjectVisual Acuitypor
dc.subjectScheimpflugpor
dc.subjectNuclear cataractpor
dc.subject.fosCiências Médicas::Medicina Básicapor
dc.subject.wosScience & Technologypor
dc.titleCorrelation between different Scheimpflug-based lens densitometry analysis and effective phacoemulsification time in mild nuclear cataractspor
dc.typearticlepor
dspace.entity.typePublicationen
oaire.citationEndPage1110por
oaire.citationIssue3por
oaire.citationStartPage1103-1110por
oaire.citationVolume38por
sdum.journalInternational Ophthalmologypor

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
faria-correia2017.pdf
Tamanho:
1.13 MB
Formato:
Adobe Portable Document Format