Aqueous two-phase micellar systems in an oscillatory flow micro-reactor: Study of perspectives and experimental performance
| dc.contributor.author | Lopes, A. M. | |
| dc.contributor.author | Silva, Daniel Pereira da | |
| dc.contributor.author | Vicente, A. A. | |
| dc.contributor.author | Pessoa Júnior, Adalberto | |
| dc.contributor.author | Teixeira, J. A. | |
| dc.date.accessioned | 2012-02-03T16:47:48Z | |
| dc.date.available | 2012-02-03T16:47:48Z | |
| dc.date.issued | 2011-09 | |
| dc.description.abstract | Aqueous two-phase micellar systems (ATPMS) are micellar surfactant solutions with physical properties that make them very efficient for the extraction/concentration of biological products. In this work the main proposal that has been discussed is the possible applicability and importance of a novel oscillatory flow micro-reactor (micro-OFR) envisaged for parallel screening and/or development of industrial bioprocesses in ATPMS. Based on the technology of oscillatory flow mixing (OFM), this batch or continuous micro-reactor has been presented as a new small-scale alternative for biological or physical-chemical applications. RESULTS: ATPMS experiments were carried out in different OFM conditions (times, temperatures, oscillation frequencies and amplitudes) for the extraction of glucose-6-phosphate dehydrogenase (G6PD) in Triton X-114/buffer with Cibacron Blue as affinity ligand. CONCLUSION: The results suggest the potential use of OFR, considering this process a promising and new alternative for the purification or pre-concentration of bioproducts. Despite the applied homogenization and extraction conditions have presented no improvements in the partitioning selectivity of the target enzyme, when at rest temperature they have influenced the partitioning behavior in Triton X-114 ATPMS. | por |
| dc.description.sponsorship | The authors acknowledge the financial support from FCT (Fundacao para a Ciencia e Tecnologia/Portugal, SFRH/BPD/26108/2005), as well as from FAPESP (Fundacao de Amparo a Pesquisa do Estado de Sao Paulo/Brasil), CNPq (Conselho Nacional de Desenvolvimento Cientifico e Tecnologico/Brasil), and CAPES (Coordenacao para Aperfeicoamento do Ensino Superior/Brasil). | por |
| dc.identifier | 0268-2575 | por |
| dc.identifier.doi | 10.1002/jctb.2642 | por |
| dc.identifier.issn | 1097-4660 | por |
| dc.identifier.uri | https://hdl.handle.net/1822/16802 | |
| dc.language.iso | eng | por |
| dc.peerreviewed | yes | por |
| dc.publisher | Wiley | por |
| dc.rights | openAccess | por |
| dc.subject | screening micro-reactor | por |
| dc.subject | oscillatory flow mixing | por |
| dc.subject | aqueous two-phase micellar system | por |
| dc.subject | triton X-114 | por |
| dc.subject | affinity ligand | por |
| dc.subject | glucose-6-phosphate dehydrogenase | por |
| dc.subject.wos | Science & Technology | por |
| dc.title | Aqueous two-phase micellar systems in an oscillatory flow micro-reactor: Study of perspectives and experimental performance | por |
| dc.type | article | por |
| dspace.entity.type | Publication | en |
| oaire.citationEndPage | 1165 | por |
| oaire.citationIssue | 9 | por |
| oaire.citationStartPage | 1159 | por |
| oaire.citationTitle | Journal of Chemical Technology and Biotechnology | por |
| oaire.citationVolume | 86 | por |
| sdum.journal | Journal of Chemical Technology and Biotechnology | por |
| sdum.publicationstatus | published | por |
Ficheiros