Use of post-earthquake damage data to calibrate, validate and compare two seismic vulnerability assessment methods for vernacular architecture

dc.contributor.authorOrtega Heras, Javierpor
dc.contributor.authorVasconcelos, Graçapor
dc.contributor.authorRodrigues, Hugopor
dc.contributor.authorCorreia, Marianapor
dc.contributor.authorFerreira, Tiago Miguelpor
dc.contributor.authorVicente, Romeupor
dc.date.accessioned2021-01-12T11:39:18Z
dc.date.available2021-01-13T07:00:23Z
dc.date.issued2019-10
dc.date.updated2020-12-30T19:14:40Z
dc.description.abstractThe paper presents and discusses the application of two large scale seismic vulnerability assessment methods on the island of Faial in Azores (Portugal). The two methods are specifically conceived to assess the seismic vulnerability of vernacular architecture. The first method follows a classical seismic vulnerability index approach and is referred as SVIVA (Seismic Vulnerability Index for Vernacular Architecture). The second method is referred as SAVVAS (Seismic Assessment of the Vulnerability of Vernacular Architecture Structures) and it is a numerical tool intended to estimate the seismic capacity of vernacular buildings in terms of seismic load factors associated with different structural damage limit states. The main reason behind the selection of Faial Island as a case study was the availability of post-earthquake reports of the building stock after the 1998 Azores earthquake, which allowed comparing the damage scenarios obtained using both methods with the post-earthquake damage data and thus helped for the calibration and validation of the two methods. The application of both methods led to a good fit between estimated versus observed damage grades, which validated their applicability as large-scale first level approaches. Moreover, as the main outcome, the paper presents the novelties of the SAVVAS method, which had not been applied before, and discusses its main advantages, namely: no need for calibration with previous post-earthquake damage data, an enhancement of the prediction capabilities, a more individualized evaluation of the buildings and the possibility to assess the seismic performance of the building in different loading directions.por
dc.description.sponsorshipThe work presented in this paper was partly financed by FEDER funds through the Competitivity and Internationalization Operational Programme - COMPETE and by national funds through FCT Foundation for Science and Technology within the scope of the project POC1-01-01-0145-FEDER-007633.por
dc.distributioninternationalpor
dc.identifier.doi10.1016/j.ijdrr.2019.101242por
dc.identifier.issn2212-4209por
dc.identifier.urihttps://hdl.handle.net/1822/69134
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherElsevierpor
dc.rightsopenAccesspor
dc.subjectSeismic vulnerability assessmentpor
dc.subjectVernacular architecturepor
dc.subjectStone masonrypor
dc.subjectVulnerability indexpor
dc.subject1998 Azores earthquakepor
dc.subject.wosScience & Technology
dc.titleUse of post-earthquake damage data to calibrate, validate and compare two seismic vulnerability assessment methods for vernacular architecturepor
dc.typearticle
dspace.entity.typePublicationen
oaire.citationVolume39por
oaire.versionAM
sdum.export.identifier7666
sdum.journalInternational Journal of Disaster Risk Reductionpor

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
Manuscript.pdf
Tamanho:
5.02 MB
Formato:
Adobe Portable Document Format
Descrição:
Accepted Manuscript