Human-in-the-loop optimization of knee exoskeleton assistance for minimizing user’s metabolic and muscular effort
| dc.contributor.author | Monteiro, Sara Margarida Alves | |
| dc.contributor.author | Figueiredo, Joana | |
| dc.contributor.author | Fonseca, Pedro | |
| dc.contributor.author | Vilas-Boas, J. Paulo | |
| dc.contributor.author | Santos, Cristina | |
| dc.date.accessioned | 2026-09-16T08:39:10Z | |
| dc.date.issued | 2024-05 | |
| dc.date.updated | 2026-08-09T20:08:39Z | |
| dc.description.abstract | Lower limb exoskeletons have the potential to mitigate work-related musculoskeletal disorders; however, they often lack user-oriented control strategies. Human-in-the-loop (HITL) controls adapt an exoskeleton’s assistance in real time, to optimize the user–exoskeleton interaction. This study presents a HITL control for a knee exoskeleton using a CMA-ES algorithm to minimize the users’ physical effort, a parameter innovatively evaluated using the interaction torque with the exoskeleton (a muscular effort indicator) and metabolic cost. This work innovates by estimating the user’s metabolic cost within the HITL control through a machine-learning model. The regression model estimated the metabolic cost, in real time, with a root mean squared error of 0.66 W/kg and mean absolute percentage error of 26% (n = 5), making faster (10 s) and less noisy estimations than a respirometer (K5, Cosmed). The HITL reduced the user’s metabolic cost by 7.3% and 5.9% compared to the zero-torque and no-device conditions, respectively, and reduced the interaction torque by 32.3% compared to a zero-torque control (n = 1). The developed HITL control surpassed a non-exoskeleton and zero-torque condition regarding the user’s physical effort, even for a task such as slow walking. Furthermore, the user-specific control had a lower metabolic cost than the non-user-specific assistance. This proof-of-concept demonstrated the potential of HITL controls in assisted walking. | eng |
| dc.description.sponsorship | This study was funded by the Fundação para a Ciência e Tecnologia (FCT) under the Stimulus of Scientific Employment with the grant 2020.03393.CEECIND, under a national support to R&D units grant through the reference project UIDB/04436/2020 and UIDP/04436/2020. | |
| dc.distribution | international | |
| dc.identifier.articlenumber | 3305 | |
| dc.identifier.citation | Monteiro, S.; Figueiredo, J.; Fonseca, P.; Vilas-Boas, J.P.; Santos, C.P. Human-in-the-Loop Optimization of Knee Exoskeleton Assistance for Minimizing User’s Metabolic and Muscular Effort. Sensors 2024, 24, 3305. https://doi.org/10.3390/s24113305 | |
| dc.identifier.doi | 10.3390/s24113305 | |
| dc.identifier.eissn | 1424-8220 | |
| dc.identifier.pmc | 38894101 | |
| dc.identifier.pmid | 38894101 | por |
| dc.identifier.uri | https://hdl.handle.net/1822/103457 | |
| dc.language.iso | eng | |
| dc.peerreviewed | yes | |
| dc.publisher | MDPI | |
| dc.relation | Microelectromechanical Systems Research Unit [UIDB/04436/2020] | |
| dc.relation | Microelectromechanical Systems Research Unit [UIDP/04436/2020] | |
| dc.relation | 2020.03393.CEECIND | |
| dc.relation.hasversion | https://www.mdpi.com/1424-8220/24/11/3305 | |
| dc.rights | openAccess | |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
| dc.subject | metabolic cost estimation | |
| dc.subject | work-related musculoskeletal disorders | |
| dc.subject | exoskeletons | |
| dc.subject | human-in-the-loop control | |
| dc.title | Human-in-the-loop optimization of knee exoskeleton assistance for minimizing user’s metabolic and muscular effort | eng |
| dc.type | article | |
| dspace.entity.type | Publication | |
| oaire.awardNumber | UIDB/04436/2020 | |
| oaire.awardNumber | UIDP/04436/2020 | |
| oaire.awardTitle | Microelectromechanical Systems Research Unit [UIDB/04436/2020] | |
| oaire.awardTitle | Microelectromechanical Systems Research Unit [UIDP/04436/2020] | |
| oaire.awardURI | https://hdl.handle.net/1822/98681 | |
| oaire.awardURI | https://hdl.handle.net/1822/97796 | |
| oaire.citation.issue | 11 | |
| oaire.citation.volume | 24 | |
| oaire.citationIssue | 11 | |
| oaire.citationVolume | 24 | |
| oaire.funderIdentifier | http://doi.org/10.13039/501100001871 | |
| oaire.funderIdentifier | http://doi.org/10.13039/501100001871 | |
| oaire.funderName | Fundação para a Ciência e a Tecnologia, I.P. | |
| oaire.funderName | Fundação para a Ciência e a Tecnologia, I.P. | |
| oaire.fundingStream | Concurso de avaliação no âmbito do Programa Plurianual de Financiamento de Unidades de I&D (2017/2018) - Financiamento Base | |
| oaire.fundingStream | Concurso de avaliação no âmbito do Programa Plurianual de Financiamento de Unidades de I&D (2017/2018) - Financiamento Programático | |
| oaire.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |
| relation.isProjectOfPublication | 966af492-6fdb-4b92-be1a-1a19ea7f0a04 | |
| relation.isProjectOfPublication | 434c1b95-4d46-4492-b1e4-42d8189ad380 | |
| relation.isProjectOfPublication.latestForDiscovery | 966af492-6fdb-4b92-be1a-1a19ea7f0a04 | |
| sdum.export.identifier | 19991 | |
| sdum.journal | Sensors |
Ficheiros
Pacote original
1 - 1 de 1
A carregar...
- Nome:
- human in the loop.pdf
- Tamanho:
- 4.14 MB
- Formato:
- Adobe Portable Document Format