Mechanical behaviour of metal anchors in historic brick masonry: an experimental approach

dc.contributor.authorMuñoz, Rosanapor
dc.contributor.authorLourenço, Paulo B.por
dc.date.accessioned2020-10-26T23:34:06Z
dc.date.available2020-10-26T23:34:06Z
dc.date.issued2019
dc.date.updated2020-10-26T13:04:13Z
dc.description.abstractMany historic buildings degrade and partially collapse due to the action of time and to lack of maintenance; only their façades remain. Their consolidation and reuse have fundamental importance to preserve the architectural heritage. In several cases, these buildings are made of brick masonry and interventions demand using metallic structures. The connection between the masonry, which has already lost its initial strength capacity, and the proposed structure must be carefully analysed to avoid structural damages to the building. The aim of the current study is to investigate the mechanical behaviour of metal anchors used to connect the walls to the metallic structure, whether provisionally or permanently, for shoring purposes or for building repairs, strengthening or rehabilitation ones. An experimental campaign was carried out; it included pull-out tests applied to two types of adhesive (chemical and grout) and mechanical anchors in brick masonry built in laboratory using hydraulic lime mortar and low mechanical strength bricks. Tensile force results were compared to predictive analytical formulas available in the literature. The current research contributes to the selection of the most efficient structural bond in terms of adhesion in historic brick masonry, thus contributing to the preservation of the historical, artistic and cultural heritage.por
dc.description.sponsorship. The authors would like to thank CAPES (Coordination for the Improvement of Higher Education Personnel) - the Brazilian public research agency that granted the postdoctoral fellowship to the first author; as well as HILTI Portugal, for making the materials and the equipment available; and the professionals working in the materials and structures laboratories at University of Minho.por
dc.distributioninternationalpor
dc.identifier.doi10.1007/978-3-319-99441-3_85por
dc.identifier.issn2211-0844
dc.identifier.urihttps://hdl.handle.net/1822/67745
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherSpringerpor
dc.relation.publisherversionhttps://link.springer.com/chapter/10.1007%2F978-3-319-99441-3_85por
dc.rightsopenAccesspor
dc.subjectBrick masonrypor
dc.subjectFailure modespor
dc.subjectMetal anchorspor
dc.subjectPull-out testspor
dc.subjectTensile forcespor
dc.subject.fosEngenharia e Tecnologia::Engenharia Civilpor
dc.titleMechanical behaviour of metal anchors in historic brick masonry: an experimental approachpor
dc.typebookPartpor
dspace.entity.typePublicationen
oaire.citationEndPage798por
oaire.citationStartPage788por
oaire.citationVolume18
sdum.export.identifier7366
sdum.journalRILEM Bookseries

Ficheiros