A review on glial fibrillary acidic protein biosensors for point-of-care stroke diagnosis

dc.contributor.authorCaetano, Leonor de Carvalho
dc.contributor.authorPinto, Vânia Cristina Gonçalves
dc.contributor.authorCatarino, Susana Oliveira
dc.date.accessioned2026-11-27T16:17:05Z
dc.date.issued2026
dc.description.abstractStroke is a major cause of mortality and disability worldwide, and rapid differentiation between IS, haemorrhagic stroke (HS), and SMs is essential for timely treatment. This narrative review examines the potential of GFAP as a biomarker for acute stroke diagnosis and evaluates biosensing strategies for its detection, with particular emphasis on PoC and pre-hospital applications, profiting from its coupling with microfluidic technologies. The biological role, temporal kinetics, and diagnostic and prognostic value of GFAP are first discussed in comparison with other stroke biomarkers. The suitability of cerebrospinal fluid (CSF), serum, plasma, whole blood, urine, saliva, and sweat as biological matrices is then assessed. Finally, electrochemical, optical, mechanical, and other biosensor platforms developed for GFAP detection are reviewed in terms of sensing principles, analytical performance, biological matrices, assay duration, and potential clinical applicability. Overall, despite the heterogeneity of the data available in the literature, the reviewed evidence supports the potential utility of GFAP for hyperacute stroke assessment, owing to its rapid elevation following ICH and its ability to differentiate HS from IS and SMs. However, variability in sampling time, analytical methods, biological matrices, and patient populations limits direct comparison between studies. Further development of integrated and multiplexed PoC biosensors, also benefiting from the wide possibilities of advanced microfluidics’ technologies, may facilitate rapid and accessible stroke diagnosis and patient stratification.eng
dc.description.sponsorshipThis research was funded by the CardioSensing project (COMPETE2030-FEDER-00689800), reference 2023.16645.ICDT (DOI: 10.54499/2023.16645.ICDT), co-financed by European Regional Development Fund (FEDER) and national funds, through Fundação para a Ciência e a Tecnologia (FCT, I.P.), through the Innovation and Digital Transition Programme—Compete2030. The authors also acknowledge the FCT partial financial support within the R&D Unit Project Scope: UIDB/04436/2025 (DOI: 10.54499/UID/04436/2025) and LA/P/0045/2020. Vânia Pinto thanks FCT for her contract funding provided through 2021.01087.CEECIND (DOI: 10.54499/2021.01087.CEECIND/CP1664/CT0020).
dc.distributioninternational
dc.identifier.articlenumber6579
dc.identifier.citationFernandes, J., Ferreira, G. M., Carmo, J. P., Minas, G., & Catarino, S. O. (2026). Numerical Characterization of Optical Transmittance Through Planar Multilayer Dielectric Stacks on CMOS Photodiodes. Sensors, 26(20), 6591. https://doi.org/10.3390/s26206591
dc.identifier.doi10.3390/s26206579
dc.identifier.eissn1424-8220
dc.identifier.urihttps://hdl.handle.net/1822/104969
dc.language.isoeng
dc.peerreviewedyes
dc.publisherMDPI
dc.relationNovel multiplexer microfluidic platform for fast molecular diagnosis of stroke [2023.16645.ICDT]
dc.relationMicroelectromechanical Systems Research Unit [UIDB/04436/2020]
dc.relationALICE - Associate Laboratory in Chemical Engineering [LA/P/0045/2020]
dc.relationMultiplexed micro(bio)sensors integrated into a microfluidic organ-on-a-chip platform for assessing innovative drug delivery [2021.01086.CEECIND/CP1664/CT0008]
dc.relation.hasversionhttps://www.mdpi.com/1424-8220/26/20/6579
dc.rightsopenAccess
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectbiomarkers
dc.subjectbiosensors
dc.subjectGFAP
dc.subjectPoint of Care detection
dc.subjectstroke diagnosis
dc.subject.fosEngenharia e Tecnologia::Engenharia Médica
dc.subject.odsSaúde de qualidade
dc.titleA review on glial fibrillary acidic protein biosensors for point-of-care stroke diagnosiseng
dc.typearticle
dspace.entity.typePublication
oaire.awardNumber2023.16645.ICDT
oaire.awardNumberUIDB/04436/2020
oaire.awardNumberLA/P/0045/2020
oaire.awardNumber2021.01086.CEECIND/CP1664/CT0008
oaire.awardTitleNovel multiplexer microfluidic platform for fast molecular diagnosis of stroke [2023.16645.ICDT]
oaire.awardTitleMicroelectromechanical Systems Research Unit [UIDB/04436/2020]
oaire.awardTitleALICE - Associate Laboratory in Chemical Engineering [LA/P/0045/2020]
oaire.awardTitleMultiplexed micro(bio)sensors integrated into a microfluidic organ-on-a-chip platform for assessing innovative drug delivery [2021.01086.CEECIND/CP1664/CT0008]
oaire.awardURIhttps://hdl.handle.net/1822/101519
oaire.awardURIhttps://hdl.handle.net/1822/98681
oaire.awardURIhttps://hdl.handle.net/1822/97443
oaire.awardURIhttps://hdl.handle.net/1822/99512
oaire.citation.issue20
oaire.citation.volume26
oaire.funderIdentifierhttp://doi.org/10.13039/501100001871
oaire.funderIdentifierhttp://doi.org/10.13039/501100001871
oaire.funderIdentifierhttp://doi.org/10.13039/501100001871
oaire.funderIdentifierhttp://doi.org/10.13039/501100001871
oaire.funderNameFundação para a Ciência e a Tecnologia, I.P.
oaire.funderNameFundação para a Ciência e a Tecnologia, I.P.
oaire.funderNameFundação para a Ciência e a Tecnologia, I.P.
oaire.funderNameFundação para a Ciência e a Tecnologia, I.P.
oaire.fundingStreamConcurso de Projetos de IC&DT em Todos os Domínios Científicos 2023
oaire.fundingStreamConcurso de avaliação no âmbito do Programa Plurianual de Financiamento de Unidades de I&D (2017/2018) - Financiamento Base
oaire.fundingStreamConcurso para Atribuição do Estatuto e Financiamento de Laboratórios Associados (LA)
oaire.fundingStreamCEEC IND4ed
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
relation.isProjectOfPublication841784e7-369e-47a9-ab00-ed41b0d16880
relation.isProjectOfPublication966af492-6fdb-4b92-be1a-1a19ea7f0a04
relation.isProjectOfPublicationa46182bc-35b4-48f7-bd4e-e8690b0db066
relation.isProjectOfPublication91c2c630-c00d-4fde-bc09-2a117998cc8a
relation.isProjectOfPublication.latestForDiscovery841784e7-369e-47a9-ab00-ed41b0d16880
sdum.journalSensors

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
sensors-26-06579 (1).pdf
Tamanho:
1.58 MB
Formato:
Adobe Portable Document Format