The seismic performance of earthen historical buildings in seismic-prone regions: The church of Santo Tomás de Aquino in Rondocan as a complex example

dc.contributor.authorMora, Elesban Nochebuena
dc.contributor.authorMendes, N.
dc.contributor.authorSalvalaggio, Matteo
dc.contributor.authorLourenço, Paulo B.
dc.date.accessioned2025-10-17T19:03:33Z
dc.date.issued2025-07-07
dc.description.abstractAdobe churches are representative of Andean architectural heritage, yet their structural vulnerability to seismic events remains a significant concern. This study evaluates the seismic performance of the 17th-century Church of Santo Tomás de Aquino in Rondocan, Peru, an adobe building that underwent conservation work in the late 1990s. The assessment combines in situ inspections and experimental testing with advanced nonlinear numerical modeling. A finite-element macro-model was developed and calibrated using sonic and ambient vibration tests to replicate the observed structural behavior. Nonlinear static (pushover) analyses were performed in the four principal directions to identify failure mechanisms and to evaluate seismic capacity using the Peruvian seismic code. Kinematic limit analyses were conducted to assess out-of-plane mechanisms using force- and displacement-based criteria. The results revealed critical vulnerabilities in the rear façade and lateral walls, particularly in terms of out-of-plane collapse, while the main façade exhibited a higher capacity but a brittle failure mode. This study illustrates the value of advanced numerical simulations, calibrated with field data, as effective tools for assessing seismic vulnerability in historic adobe buildings. The outcomes highlight the necessity of strengthening measures to balance life safety requirements with preservation goals.eng
dc.description.sponsorshipThis work is partially funded by the Getty Conservation Institute—Seismic Retrofitting Project. The study is also funded by the STAND4HERITAGE project (new STANDards FOR seismic assessment of built cultural HERITAGE) that has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation program (Grant No. 833123) as an Advanced Grant. This study is also partially funded by national funds (PIDDAC) under the R&D Unit Institute for Sustainability and Innovation in Structural Engineering (ISISE) under reference UIDB/04029/2020 (https://doi.org/10.54499/UIDB/04029/2020) and from the Associate Laboratory Advanced Production and Intelligent Systems ARISE under reference LA/P/0112/2020. The opinions and conclusions presented in this paper are those of the authors and do not necessarily reflect the views of the sponsoring organizations.
dc.distributioninternational
dc.identifier.citationNochebuena-Mora E., Mendes N., Salvalaggio M., Lourenço P.B. (2025), Seismic performance of earthen historical buildings in seismic-prone regions: The Church of Santo Tomás de Aquino in Rondocan as a complex example, Applied Sciences, 15(13), 7624, MDPI.
dc.identifier.doi10.3390/app15137624
dc.identifier.eissn20763417
dc.identifier.urihttps://hdl.handle.net/1822/97641
dc.language.isoeng
dc.peerreviewedyes
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relationNew STANDards for seismic assessment of built cultural HERITAGE [833123]
dc.relationInstitute for Sustainability and Innovation in Structural Engineering [UIDB/04029/2020]
dc.relationAdvanced Production and Intelligent Systems [LA/P/0112/2020]
dc.relation.hasversionhttps://www.mdpi.com/2076-3417/15/13/7624
dc.rightsopenAccess
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectadobe church
dc.subjecthistoric masonry building
dc.subjectFEM modeling
dc.subjectmodel calibration
dc.subjectstatic nonlinear analysis
dc.subjectkinematic analysis
dc.subjectseismic safety assessment
dc.subject.fosEngenharia e Tecnologia::Engenharia Civil
dc.titleThe seismic performance of earthen historical buildings in seismic-prone regions: The church of Santo Tomás de Aquino in Rondocan as a complex exampleeng
dc.typearticle
dspace.entity.typePublication
oaire.awardNumber833123
oaire.awardNumberUIDB/04029/2020
oaire.awardNumberLA/P/0112/2020
oaire.awardTitleNew STANDards for seismic assessment of built cultural HERITAGE [833123]
oaire.awardTitleInstitute for Sustainability and Innovation in Structural Engineering [UIDB/04029/2020]
oaire.awardTitleAdvanced Production and Intelligent Systems [LA/P/0112/2020]
oaire.awardURIhttps://hdl.handle.net/1822/97482
oaire.awardURIhttps://hdl.handle.net/1822/97640
oaire.awardURIhttps://hdl.handle.net/1822/97535
oaire.citationIssue13por
oaire.citationVolume15por
oaire.funderIdentifierhttps://doi.org/10.13039/501100000780
oaire.funderIdentifierhttp://doi.org/10.13039/501100001871
oaire.funderIdentifierhttp://doi.org/10.13039/501100001871
oaire.funderNameEuropean Commission
oaire.funderNameFundação para a Ciência e a Tecnologia, I.P.
oaire.funderNameFundação para a Ciência e a Tecnologia, I.P.
oaire.fundingStreamH2020
oaire.fundingStreamConcurso de avaliação no âmbito do Programa Plurianual de Financiamento de Unidades de I&D (2017/2018) - Financiamento Base
oaire.fundingStreamConcurso para Atribuição do Estatuto e Financiamento de Laboratórios Associados (LA)
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
relation.isProjectOfPublication669dc326-a3cd-4d8b-830a-9c29aa3b389f
relation.isProjectOfPublicationed595047-c351-4468-b4ed-fe3fcff0c00b
relation.isProjectOfPublication3959633d-5d07-4df3-80e7-77956772f5bf
relation.isProjectOfPublication.latestForDiscovery669dc326-a3cd-4d8b-830a-9c29aa3b389f
sdum.journalApplied Sciences

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
applsci-15-07624.pdf
Tamanho:
5.8 MB
Formato:
Adobe Portable Document Format