Evaluating retinal image quality for myopia control lenses in a synthetic accommodative wavefront model

dc.contributor.authorGarcía, María Mechó
dc.contributor.authorGonzález-Méijome, José Manuel
dc.contributor.authorFernandes, Paulo
dc.contributor.authorFaria Ribeiro, Miguel
dc.date.accessioned2026-11-23T10:55:40Z
dc.date.issued2026
dc.description.abstractThis study uses a wavefront model to evaluate the effects of contact lenses on retinal image quality (RIQ) as a function of target vergence (TV). Three hundred synthetic eyes were generated using an accommodative wavefront model to simulate the changes in RIQ with accommodation. The synthetic eyes wavefronts were computationally combined using direct wavefront summation with two myopia control CLs. One has a +2.00D treatment zone dual-focus (DF) design (MiSight), and the other has an extended depth of focus (EDOF) design (Mylo). Peak image quality was calculated for the naked eye, with CLs in the relaxed state, and for an accommodative demand of -2.5D. Additionally, the predicted accommodative response (change in accommodative response that maximizes RIQ) was calculated. The mean RIQ (normalized between 0 and 1) for the relaxed eye was 0.42 ± 0.10 in the naked eye. It decreased to 0.26 ± 0.05 with the DF and threefold to 0.15 ± 0.04 with the EDOF. For a TV = -2.5D, the RIQ was 0.34 ± 0.09 in the naked eye condition, 0.24 ± 0.07 with the DF, and 0.19 ± 0.03 with the EDOF. For the TV, the CL’s effective add power, the accommodative RIQ showed a secondary peak, with RIQs of 0.08 ± 0.03 (DF) and 0.12 ± 0.04 (EDOF). The theoretical accommodative response (AR) of the naked eye was 2.33 ± 0.20 D, while with the DF and EDOF, it was 2.23 ± 0.39 D and 1.75 ± 0.22 D, respectively. Both myopia control CLs reduced RIQ at a TV of 0 D. At a TV = -2.5D; both lenses caused a secondary peak in the RIQ through focus. With EDOF, the secondary peak was less than 0.1 D from the maximum peak, likely due to its EDOF design. The theoretical AR was reduced with both myopia control CLs, 0.27 D for DF CLs and 0.75 D for EDOF CLs. These results indicate that both lenses impose significant limitations on RIQ and theoretical AR, align with findings from previous studies on subjective optical performance, and validate the model as a useful testing tool.eng
dc.description.sponsorshipH2020 Marie Skłodowska-Curie Actions (956720).
dc.distributioninternational
dc.identifier.citationMechó-García, M., Fernandes, P., González- Méijome, J. M., & Faria-Ribeiro, M. (2025). Evaluating retinal image quality for myopia control lenses in a synthetic accommodative wavefront model. Biomedical Optics Express, 17(1), 394. https://doi.org/10.1364/boe.549285
dc.identifier.doi10.1364/BOE.549285
dc.identifier.eissn2156-7085
dc.identifier.urihttps://hdl.handle.net/1822/104833
dc.language.isoeng
dc.peerreviewedyespor
dc.publisherOptica Publishing Group
dc.relationOpto-Biomechanical Eye Research Network [956720]
dc.relation.hasversionhttps://opg.optica.org/boe/fulltext.cfm?uri=boe-17-1-394
dc.rightsopenAccess
dc.rights.urihttp://creativecommons.org/licenses/by-sa/4.0/
dc.subject.fosCiências Naturais::Ciências Físicas
dc.titleEvaluating retinal image quality for myopia control lenses in a synthetic accommodative wavefront modeleng
dc.typearticlepor
dspace.entity.typePublication
oaire.awardNumber956720
oaire.awardTitleOpto-Biomechanical Eye Research Network [956720]
oaire.awardURIhttps://hdl.handle.net/1822/98711
oaire.funderIdentifierhttps://doi.org/10.13039/501100000780
oaire.funderNameEuropean Commission
oaire.fundingStreamH2020
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
relation.isProjectOfPublication86b69b1a-75e8-4bbf-a4ad-59f238fab3da
relation.isProjectOfPublication.latestForDiscovery86b69b1a-75e8-4bbf-a4ad-59f238fab3da
sdum.journalBiomedical Optics Express

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
Mechó_2025(Evaluating Retinal Image Quality for Myopia Control Lenses in a Synthetic AccommodativeWavefront Model).pdf
Tamanho:
603.22 KB
Formato:
Adobe Portable Document Format