Influence of climate on clinical diagnostic dry eye tests: pilot study

dc.contributor.authorTesón, Marisapor
dc.contributor.authorLópez-Miguel, Albertopor
dc.contributor.authorNeves, Helenapor
dc.contributor.authorCalonge, Margaritapor
dc.contributor.authorGonzález-García, María J.por
dc.contributor.authorGonzález-Méijome, José Manuelpor
dc.date.accessioned2016-01-13T15:12:31Z
dc.date.available2016-01-13T15:12:31Z
dc.date.issued2015
dc.date.updated2015-12-26T21:42:40Z
dc.description.abstractPurpose. To analyze dry eye disease (DED) tests and their consistency in similar nonsymptomatic population samples living in two geographic locations with different climates (Continental vs. Atlantic). Methods. This is a pilot study including 14 nonsymptomatic residents from Valladolid (Continental climate, Spain) and 14 sex-matched and similarly aged residents from Braga (Atlantic climate, Portugal); they were assessed during the same season (spring) of two consecutive years. Phenol red thread test, conjunctival hyperemia, fluorescein tear breakup time, corneal and conjunctival staining, and Schirmer test were evaluated on three different consecutive visits. Reliability was assessed using the intraclass correlation coefficient and weighted kappa (J) coefficient for quantitative and ordinal variables, respectively. Results. Fourteen subjects were recruited in each city with a mean (TSD) age of 63.0 (T1.7) and 59.1 (T0.9) years (p = 0.08) in Valladolid and Braga, respectively. Intraclass correlation coefficient and J values of the tests performed were below 0.69 and 0.61, respectively, for both samples, thus showing moderate to poor reliability. Subsequently, comparisons were made between the results corresponding to the middle and higher outdoor relative humidity (RH) visit in each location as there were no differences in mean temperature (p Q 0.75) despite RH values significantly differing (p e 0.005). Significant (p e 0.05) differences were observed between Valladolid and Braga samples on tear breakup time (middle RH visit, 2.76 T 0.60 vs. 5.26 T 0.64 seconds; higher RH visit, 2.61 T 0.32 vs. 5.78 T 0.88 seconds) and corneal (middle RH, 0.64 T 0.17 vs. 0.14 T 0.10; higher RH, 0.60 T 0.22 vs. 0.0 T 0.0) and conjunctival staining (middle RH, 0.61 T 0.17 vs. 0.14 T 0.08; higher RH, 0.57 T 0.15 vs. 0.18 T 0.09). Conclusions. This pilot study provides initial evidence to support that DED test outcomes assessing the ocular surface integrity and tear stability are climate dependent. Future large-sample studies should support these outcomes also in DED patients. This knowledge is fundamental for multicenter clinical trials. Lack of consistency in diagnostic clinical tests for DED was also corroborated. (Optom Vis Sci 2015;92:e284Ye289)por
dc.description.sponsorshipThe authors thank M. Eugenia Mateo for statistical advice. The present study was supported by grants from Junta de Castilla y Leo´n: Grupos de Excelencia (GR217), EDU-VA145A11-2, and University of Valladolid FPI-UVa-2008. This study was also funded by FEDER through the COMPETE Program and by the Portuguese Foundation for Science and Technology (FCT) in the framework of projects PTDC/SAU-BEB/098391/ 2008, PTDC/SAU-BEB/098392/2008, and the Strategic Project PESTC/FIS/UI607/2011. No funding organizations had a role in the design or conduct of this research.por
dc.distributioninternationalpor
dc.identifier.citationTesón, Marisa; López-Miguel, Alberto; Neves, Helena; Calonge, Margarita; González-García, María J.; González-Méijome, José M.Influence of Climate on Clinical Diagnostic Dry Eye Tests, Optometry and Vision Science, 92, 9, e284-e289, 2015.por
dc.identifier.doi10.1097/OPX.0000000000000673por
dc.identifier.issn1040-5488por
dc.identifier.pmid26204472por
dc.identifier.urihttps://hdl.handle.net/1822/39416
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherAmerican Academy of Optometry (AAOPT)por
dc.relationEDU-VA145A11-2por
dc.relationinfo:eu-repo/grantAgreement/FCT/5876-PPCDTI/98391/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/5876-PPCDTI/98392/PTpor
dc.relationPEST-C/FIS/UI607/2011por
dc.rightsopenAccesspor
dc.subjectDry eye diseasepor
dc.subjectDiagnostic testpor
dc.subjectEnvironmental conditionspor
dc.subjectReliabilitypor
dc.subject.wosScience & Technologypor
dc.titleInfluence of climate on clinical diagnostic dry eye tests: pilot studypor
dc.typearticle
dspace.entity.typePublicationen
oaire.citationEndPagee289por
oaire.citationIssue9por
oaire.citationStartPagee284por
oaire.citationTitleOptometry and Vision Sciencepor
oaire.citationVolume92por
sdum.journalOptometry and Vision Sciencepor
sdum.publicationstatuspublishedpor

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
5.5.115. TESÓN_15_OVS (Braga-Valladolid Dry Eye).pdf
Tamanho:
120.72 KB
Formato:
Adobe Portable Document Format