The influence of cycloplegic in objective refraction
| dc.contributor.author | Jorge, Jorge | |
| dc.contributor.author | Queirós, A. | |
| dc.contributor.author | González-Méijome, José Manuel | |
| dc.contributor.author | Fernandes, Paulo Rodrigues | |
| dc.contributor.author | Almeida, José B. | |
| dc.contributor.author | Parafita, Manuel A. | |
| dc.date.accessioned | 2006-11-16T16:10:03Z | |
| dc.date.available | 2006-11-16T16:10:03Z | |
| dc.date.issued | 2005-07 | |
| dc.description.abstract | The purpose of this study was to compare refractions measured with an autorefractor and retinoscopy in cycloplegic and non-cycloplegic eyes. The objective refractions were performed in 199 right eyes from 199 healthy young adults with a mean age of 21.6 ±2.66 years. The measurements were performed first without cycloplegia and repeated 30 minutes later with cycloplegia. Data were analyzed using Fourier decomposition of the power profile. More negative values of component M and J0 were give by non-cycloplegic autorefraction compared to cycloplegic autorefraction (p<0.001). However more positive values were given by non-cycloplegic autorefraciton regarding to the J45 vector, althought this differences were not statistically significant (p=0.233). Regarding retinoscopy, more negative values of component M where obtained with non-cycloplegic retinoscopy (p<0.001); for the cylindrical vectors J0 and J45 the retinoscopy without cycloplegic yields more negative values (p= 0.234; p= 0.112, respectively). Accepting that differences between cycloplegic and non-cycloplegic retinoscopy are only due to accommodative response, present results confirm that when performed by an experienced clinician, retinoscopy is a more reliable method to obtain objective start point for refraction under non-cycloplegic conditions. | eng |
| dc.distribution | international | eng |
| dc.identifier.citation | "Ophthalmic and physiological optics". ISSN 1040-5488. 25:4 (July 2005) 340-345. | eng |
| dc.identifier.doi | 10.1111/j.1475-1313.2005.00277.x | por |
| dc.identifier.issn | 1040-5488 | eng |
| dc.identifier.pmid | 15953119 | por |
| dc.identifier.uri | https://hdl.handle.net/1822/5793 | |
| dc.language.iso | eng | eng |
| dc.peerreviewed | yes | eng |
| dc.publisher | Blackwell Publishing | eng |
| dc.rights | openAccess | eng |
| dc.subject | Astigmatism | eng |
| dc.subject | Autorefractor | eng |
| dc.subject | Retinoscopy | eng |
| dc.subject | Refractive errors | eng |
| dc.subject | Cycloplegic | eng |
| dc.subject | Non-cycloplegic refraction | eng |
| dc.subject | cycloplegic and non-cycloplegic refraction | por |
| dc.subject.wos | Science & Technology | por |
| dc.title | The influence of cycloplegic in objective refraction | eng |
| dc.type | article | por |
| dspace.entity.type | Publication | en |
| oaire.citationEndPage | 345 | por |
| oaire.citationIssue | 4 | por |
| oaire.citationStartPage | 340 | por |
| oaire.citationVolume | 25 | por |
| sdum.journal | Ophthalmic and physiological optics | por |
| sdum.number | 4 | eng |
| sdum.pagination | 340-345 | eng |
| sdum.publicationstatus | published | eng |
| sdum.volume | 25 | eng |
Ficheiros
Pacote original
1 - 1 de 1
A carregar...
- Nome:
- The influence of cycloplegic in objective refraction.pdf
- Tamanho:
- 102.46 KB
- Formato:
- Adobe Portable Document Format
- Descrição:
- article