Automatic modeling of pectus excavatum corrective prosthesis using artificial neural networks

dc.contributor.authorRodrigues, Pedro L.por
dc.contributor.authorRodrigues, Nuno F.por
dc.contributor.authorPinho, A. C. Marques depor
dc.contributor.authorFonseca, Jaime C.por
dc.contributor.authorPinto, Jorge Correiapor
dc.contributor.authorVilaça, João L.por
dc.date.accessioned2015-01-15T18:26:26Z
dc.date.available2015-01-15T18:26:26Z
dc.date.issued2014
dc.date.updated2015-01-15T12:09:24Z
dc.description.abstractPectus excavatum is the most common deformity of the thorax. Pre-operative diagnosis usually includes Computed Tomography (CT) to successfully employ a thoracic prosthesis for anterior chest wall remodeling. Aiming at the elimination of radiation exposure, this paper presents a novel methodology for the replacement of CT by a 3D laser scanner (radiation-free) for prosthesis modeling. The complete elimination of CT is based on an accurate determination of ribs position and prosthesis placement region through skin surface points. The developed solution resorts to a normalized and combined outcome of an artificial neural network (ANN) set. Each ANN model was trained with data vectors from 165 male patients and using soft tissue thicknesses (STT) comprising information from the skin and rib cage (automatically determined by image processing algorithms). Tests revealed that ribs position for prosthesis placement and modeling can be estimated with an average error of 5.0±3.6mm. One also showed that the ANN performance can be improved by introducing a manually determined initial STT value in the ANN normalization procedure (average error of 2.82±0.76mm). Such error range is well below current prosthesis manual modeling (approximately 11mm), which can provide a valuable and radiation-free procedure for prosthesis personalization.por
dc.description.sponsorshipThe authors acknowledge to Foundation for Science and Technology (FCT)-Portugal for the fellowships with references: SFRH/BD/74276/2010 and PTDC/SAU-BEB/103368/2008.por
dc.distributioninternationalpor
dc.identifier.doi10.1016/j.medengphy.2014.06.020por
dc.identifier.issn1350-4533por
dc.identifier.pmid25070021por
dc.identifier.urihttps://hdl.handle.net/1822/32918
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherElsevierpor
dc.relation.publisherversionhttp://www.sciencedirect.com/science/article/pii/S1350453314001799por
dc.rightsopenAccesspor
dc.subjectPectus excavatumpor
dc.subjectArtificial neural networkspor
dc.subjectImage segmentationpor
dc.subjectProsthesis 45 modellingpor
dc.subjectProsthesis modellingpor
dc.subject.wosScience & Technologypor
dc.titleAutomatic modeling of pectus excavatum corrective prosthesis using artificial neural networkspor
dc.typearticle
dspace.entity.typePublicationen
oaire.citationEndPage1345por
oaire.citationIssue10por
oaire.citationStartPage1338por
oaire.citationTitleMedical Engineering & Physicspor
oaire.citationVolume36por
sdum.journalMedical Engineering & Physicspor
sdum.publicationstatuspublishedpor

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
rodrigues pl_med eng phys 2014 prep.pdf
Tamanho:
840.62 KB
Formato:
Adobe Portable Document Format