dc.description.abstractPurpose: To show the utility of high resolution spectral domain optical coherence tomography (HR SOCT) for the in situ evaluation of epithelial, stromal and contact lens (CL) thickness changes under closed-eye conditions without lens removal. Settings: Clinical and Experimental Optometry Research Lab, University of Minho, Portugal. Methods: Eight young healthy patients wore a thick soft CL during 90 minutes under closed-eye conditions and measures of epithelial and stromal corneal thickness were obtained at regular intervals using a HR SOCT (Copernicus HR, Optopol Tech. SA, Poland). Results: Minimal changes in epithelial thickness were detected with a transient statistically significant increase in epithelial thickness in the fellow control eye 30 minutes after insertion (p=0.028). A significant and progressive increase in stromal thickness up to 8% after 90 minutes of lens wear was observed at a constant rate of 2.5% 50 every 30 minutes, being statistically significant in all observations (p<0.001). Fellow control eye also showed a significant increase in stromal thickness at a much lower rate of 0.5% every 30 minutes. Lens thickness decreased significantly by 2% after 90 minutes of lens wear under closed eye conditions (p<0.001). Individual analysis showed that all eyes displayed stromal swelling, while only half of them showed epithelial swelling. Conclusion: Increase in stromal thickness and a slight decrease in lens thickness were observed in response to a hypoxic stimulus under closed eye conditions. High resolution spectral domain HR SOCT is a powerful tool to investigate in vivo the physiological interactions between cornea and contact lenses.por
dc.description.sponsorshipSupported in part by research grants to A. Cervino from the Universitat de Valencia (UV-AE-20070225), the "Jose Castillejo" Research Grant from the Spanish Ministry of Science and Technology (JC2008-00078) and the Spanish Network for Research in Optometry (SAF2008-01114-E).por
dc.identifier.doi10.1097/ICO.0b013e31823f0905por
dc.identifier.issn0277-3740por
dc.identifier.pmid22240923por
dc.identifier.urihttps://hdl.handle.net/1822/13779
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherLippincott, Williams & Wilkinspor
dc.relation.publisherversionhttp://journals.lww.com/corneajrnl/pages/default.aspxpor
dc.rightsopenAccesspor
dc.subjectCoherence tomographypor
dc.subjectCorneapor
dc.subjectOCTpor
dc.subjectstromal thicknesspor
dc.subjectepithelial thicknesspor
dc.subjectedemapor
dc.subjectcontact lensespor
dc.subject.wosScience & Technologypor
dc.title“In situ” corneal and contact lens thickness changes with high resolution OCTpor
dc.typearticlepor
dspace.entity.typePublicationen
oaire.citationEndPage638por
oaire.citationIssue6por
oaire.citationStartPage633por
oaire.citationTitleCorneapor
oaire.citationVolume31por
sdum.journalCorneapor
sdum.publicationstatusin publicationpor

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
5.5.65b. GONZALEZ-MEIJOME_11_CORNEA (SOCT Epithelial Stromal CL Thickness Changes Overnight).pdf
Tamanho:
1.02 MB
Formato:
Adobe Portable Document Format