“In situ” corneal and contact lens thickness changes with high resolution OCT
| dc.contributor.author | González-Méijome, José Manuel | |
| dc.contributor.author | Cerviño, Alejandro | |
| dc.contributor.author | Peixoto-de-Matos, S. C. | |
| dc.contributor.author | Madrid-Costa, David | |
| dc.contributor.author | Jorge, Jorge | |
| dc.contributor.author | Ferrer-Blasco, Teresa | |
| dc.date.accessioned | 2011-10-06T13:46:29Z | |
| dc.date.available | 2011-10-06T13:46:29Z | |
| dc.date.issued | 2012 | |
| dc.date.submitted | 2010-07-10 | |
| dc.description.abstract | Purpose: To show the utility of high resolution spectral domain optical coherence tomography (HR SOCT) for the in situ evaluation of epithelial, stromal and contact lens (CL) thickness changes under closed-eye conditions without lens removal. Settings: Clinical and Experimental Optometry Research Lab, University of Minho, Portugal. Methods: Eight young healthy patients wore a thick soft CL during 90 minutes under closed-eye conditions and measures of epithelial and stromal corneal thickness were obtained at regular intervals using a HR SOCT (Copernicus HR, Optopol Tech. SA, Poland). Results: Minimal changes in epithelial thickness were detected with a transient statistically significant increase in epithelial thickness in the fellow control eye 30 minutes after insertion (p=0.028). A significant and progressive increase in stromal thickness up to 8% after 90 minutes of lens wear was observed at a constant rate of 2.5% 50 every 30 minutes, being statistically significant in all observations (p<0.001). Fellow control eye also showed a significant increase in stromal thickness at a much lower rate of 0.5% every 30 minutes. Lens thickness decreased significantly by 2% after 90 minutes of lens wear under closed eye conditions (p<0.001). Individual analysis showed that all eyes displayed stromal swelling, while only half of them showed epithelial swelling. Conclusion: Increase in stromal thickness and a slight decrease in lens thickness were observed in response to a hypoxic stimulus under closed eye conditions. High resolution spectral domain HR SOCT is a powerful tool to investigate in vivo the physiological interactions between cornea and contact lenses. | por |
| dc.description.sponsorship | Supported in part by research grants to A. Cervino from the Universitat de Valencia (UV-AE-20070225), the "Jose Castillejo" Research Grant from the Spanish Ministry of Science and Technology (JC2008-00078) and the Spanish Network for Research in Optometry (SAF2008-01114-E). | por |
| dc.identifier.doi | 10.1097/ICO.0b013e31823f0905 | por |
| dc.identifier.issn | 0277-3740 | por |
| dc.identifier.pmid | 22240923 | por |
| dc.identifier.uri | https://hdl.handle.net/1822/13779 | |
| dc.language.iso | eng | por |
| dc.peerreviewed | yes | por |
| dc.publisher | Lippincott, Williams & Wilkins | por |
| dc.relation.publisherversion | http://journals.lww.com/corneajrnl/pages/default.aspx | por |
| dc.rights | openAccess | por |
| dc.subject | Coherence tomography | por |
| dc.subject | Cornea | por |
| dc.subject | OCT | por |
| dc.subject | stromal thickness | por |
| dc.subject | epithelial thickness | por |
| dc.subject | edema | por |
| dc.subject | contact lenses | por |
| dc.subject.wos | Science & Technology | por |
| dc.title | “In situ” corneal and contact lens thickness changes with high resolution OCT | por |
| dc.type | article | por |
| dspace.entity.type | Publication | en |
| oaire.citationEndPage | 638 | por |
| oaire.citationIssue | 6 | por |
| oaire.citationStartPage | 633 | por |
| oaire.citationTitle | Cornea | por |
| oaire.citationVolume | 31 | por |
| sdum.journal | Cornea | por |
| sdum.publicationstatus | in publication | por |
Ficheiros
Pacote original
1 - 1 de 1
A carregar...
- Nome:
- 5.5.65b. GONZALEZ-MEIJOME_11_CORNEA (SOCT Epithelial Stromal CL Thickness Changes Overnight).pdf
- Tamanho:
- 1.02 MB
- Formato:
- Adobe Portable Document Format