Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/25707

Registo completo
Campo DCValorIdioma
dc.contributor.authorPereira, Tiago-
dc.contributor.authorCarvalho, Helder-
dc.contributor.authorCatarino, André P.-
dc.contributor.authorDias, M. J.-
dc.contributor.authorPostolache, Octavian-
dc.contributor.authorGirão, Pedro S.-
dc.date.accessioned2013-10-15T11:20:02Z-
dc.date.available2013-10-15T11:20:02Z-
dc.date.issued2013-
dc.identifier.isbn978-1-4673-5197-3-
dc.identifier.urihttps://hdl.handle.net/1822/25707-
dc.description.abstractThe development of mobile systems for monitoring bioelectric signals outside a hospital environment involves many challenges that do not arise when it is in a controlled environment, like a hospital. The dimensions of these systems are an important factor to consider in order to facilitate their use without interfering with the daily activities of individuals. The purpose of this work is the implementation of a single-supply battery-powered, low power ECG/EMG signal monitoring system based on the ADS1198 Analog Front-End from Texas Instruments. The system was designed to acquire ECG signals from three electrodes using the integrated Right-Leg-Drive (RLD) circuit from the ADS1198. The developed analog front-end was connected for testing purposes through the SPI interface to a NI-USB 8451 board and signals were acquired using LabVIEW. The circuit was tested in several situations and proved to provide high quality signals using textile integrated electrodes and conventional disposable gel electrodes.por
dc.description.sponsorshipFEDER- “Programa Operacional Factores de Competitividade – COMPETE”, FCT - Fundação para a Ciência e a Tecnologia, projects PEst-C/CTM/UI0264/2011 and PTDC/EEA-ELC/70803/2006, and Instituto de Telecomunicaçõespor
dc.language.isoengpor
dc.publisherIEEEpor
dc.rightsopenAccesspor
dc.subjectECGpor
dc.subjectEMGpor
dc.subjectBiopotential measurementpor
dc.subjecte-textilespor
dc.titleWearable biopotential measurement using the TI ADS1198 analog front-end and textile electrodes : signal conditioning and signal quality assessmentpor
dc.typeconferencePaper-
dc.peerreviewedyespor
dc.relation.publisherversionhttp://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6549761por
sdum.publicationstatuspublishedpor
oaire.citationConferenceDate04 - 05 Maio 2013por
sdum.event.typeconferencepor
oaire.citationStartPage325por
oaire.citationEndPage330por
oaire.citationConferencePlaceGatineau, Quebec, Canadapor
oaire.citationTitle2013 IEEE International Symposium on Medical Measurements and Applications (MeMeA)por
dc.identifier.doi10.1109/MeMeA.2013.6549761por
dc.subject.wosScience & Technologypor
sdum.conferencePublication2013 IEEE International Symposium on Medical Measurements and Applications (MeMeA)por
Aparece nas coleções:DET/2C2T - Comunicações em congressos internacionais com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
MeMeA2013_IEEEXplore.pdfPaper1,72 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID