dc.identifier.citationOliveira M., Bragança L., Paixão D., Santos J. P. Study of double windows efficiency in order to improve sound insulation in buildings, SBE Series 16 - Brazil & Portugal, Vol. 1, pp. 343, 2016-
dc.identifier.urihttps://hdl.handle.net/1822/43183-
dc.description.abstractThe aim of this research is to evaluate sound insulation behavior of double windows, when windows, when a second window is placed upon a previous one, keeping an air layer between them. This was done through standard tests carried out at the insulation chamber of the Acoustics Laboratory of Federal University of Santa Maria in accordance with international norms ISO 10140-2 and ISO 717-1. First, low air hermetic windows were duplicated, each one having Rw = 18 dB. Second, good air hermetic windows were duplicated. The objective, through this technique, was to find out sound insulation improvement of double windows under the two mentioned circumstances. It was verified that low air hermetic double window obtained Rw = 26 dB, with an increase of 8 dB in relation to just one window of the same typology. In relation to good air hermetic double window, a Rw final of 37 dB was obtained, considering that the increase in sound insulation depends on the initial performance of the first installed window. The gain in insulation in the second instance was between 4 to 8 dB, mainly in relation to low and medium frequencies. Therefore, it was possible to quantify which sound insulation improvement could be done on façades employing the technique of double windows in order to contribute to the improvement and quality of buildings in Brazil.por
dc.language.isoengpor
dc.rightsopenAccesspor
dc.subjectAcousticspor
dc.subjectDouble windowspor
dc.subjectSound insulationpor
dc.titleStudy of double windows efficiency in order to improve sound insulation in buildingspor
dc.typeconferencePaper-
dc.peerreviewedyespor
dc.relation.publisherversionhttp://sbe16.civil.uminho.pt/app/?s=Study+of+double+windows+efficiency+in+order+to+improve+sound+insulation+in+buildings&submit=Searchpor
dc.commentshttp://ctac.uminho.pt/node/2441por
sdum.publicationstatusinfo:eu-repo/semantics/publishedVersionpor
oaire.citationConferenceDate7 Set. - 9 Set. 2016por
sdum.event.typeconferencepor
oaire.citationStartPage343por
oaire.citationEndPage350por
oaire.citationConferencePlaceVitória, Brazilpor
oaire.citationTitleSBE Series 16 - Brazil & Portugal: Sustainable Urban Communities towards a Nearly Zero Impact Built Environmentpor
oaire.citationVolume1-
dc.date.updated2016-11-22T17:58:32Z-
dc.subject.fosEngenharia e Tecnologia::Engenharia Civilpor
sdum.conferencePublicationSBE Series 16 - Brazil & Portugal: Sustainable Urban Communities towards a Nearly Zero Impact Built Environmentpor
Aparece nas coleções:C-TAC - Comunicações a Conferências Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
2441-SBE16-Brazil-Portugal-Vol_1-Pag_343.pdf1,35 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID