Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/84593

TítuloAvaliação do desempenho de colas como meio de adesão em couros naturais
Outro(s) título(s)Evaluation of the performance of glues as a mean of adhesion to natural leathers
Autor(es)Santos, Patrícia Cristina Pinto dos
Orientador(es)Geraldo, Dulce
Soares, Stephanie Christelle Marinho
Palavras-chaveAdesão
Cola
Couro
Performance
Adhesion
Glue
Leather
Data20-Dez-2022
Resumo(s)O trabalho aqui presente foi desenvolvido na ATEPELI – Ateliers de Portugal, uma empresa especializada na produção de componentes de marroquinaria de luxo, no âmbito do Projeto Individual do 2º ano de Mestrado em Técnicas de Caracterização e Análise Química. Teve como objetivo comparar o desempenho de colas utilizadas na empresa, AA1 e AA2, com a cola AQ Contact, AQc, para a possível resolução de problemas recorrentes na produção de componentes constituídos por peles naturais e croute. Neste trabalho, foram produzidas amostras planas de acordo com a norma ISO 2411: 2017, mas também componentes atualmente produzidos pela empresa. Foram feitos testes de adesão e de tração, que avaliam a resistência de adesão na separação de complexos planos e a força mínima para romper componentes, respetivamente. Em paralelo, foram realizados testes climáticos para avaliar o efeito de temperatura e humidade relativa elevadas, na performance da cola nas amostras produzidas. O desempenho das colas foi avaliado nos complexos planos e nos componentes recorrendo ao teste t e foram realizados teste de Youden para identificar as grandezas com maior influência na sua performance. Nos resultados obtidos, no complexo plano I, a cola AQc reativada, AQc r, destacou-se com os melhores resultados, enquanto a cola AA2, obteve os piores, de uma forma global. No complexo plano II, as colas AA1 e AQc, obtiveram uma performance semelhante não sendo evidenciado diferenças significativas. Apenas as amostras produzidas com a cola AQc que foram sujeitas a teste climático se destacaram. No componente designado por poignée, as colas obtiveram resultados semelhantes, nos resultados sem e com teste climático. Por último, nos resultados obtidos no lien, apenas a AQc ultrapassou o valor alvo, no tipo de couro C2. Mas destacou-se pela negativa, devido às amostras descolarem nos locais de maior tensão/torção da peça após o teste climático. Desta forma, foi concluído que a nova cola AQc não se encontra otimizada de forma a competir com as colas atualmente utilizadas, devido aos variados problemas a nível de produção, aconselhando-se a rever os métodos de utilização das colas atualmente empregadas na empresa, tentando, assim, melhorar a sua performance.
The work here presented was developed at ATEPELI – Ateliers de Portugal, a company specialized in the production of luxury leather goods, within the scope of the Individual Project of the 2nd year of the Masters in Characterization Techniques and Chemical Analysis. It aimed to compare the performance of glues used in the company, AA1 and AA2, with AQ Contact glue, AQc, for the possible resolution of recurring problems in the production of components made of natural leathers and croute. In this work, flat samples were produced according to the ISO 2411: 2017 standard, but also components currently manufactured by the company. Adhesion and traction tests were performed, which evaluate the adhesion strength in the separation of flat complexes and the minimum force to break components, respectively. In parallel, climatic tests were carried out to assess the effect of high temperature and high relative humidity on the performance of the glue in the samples produced. The performance of the glues was evaluated in the flat complexes and in the components, by using the t test and the Youden test, to identify the factors with the greatest influence on their performance. In the results obtained, in the flat complex I, the reactivated AQc glue, AQc r, stood out with the best results, while the AA2 glue, obtained the worst, in a global way. In the flat complex II, the AA1 and AQc glues obtained a similar performance, with no significant differences being evidenced. Only samples produced with the AQc glue that were subjected to climate testing stood out. In the component called poignée, the glues obtained similar results, in the results without and with climate test. Finally, in the results obtained in the lien, only the AQc exceeded the target value, in the C2 leather type. But it stood out in a negative way, due to the samples ungluing in the places of greater tension/torsion of the lien after the climatic test. In this way, it was concluded that the new AQc glue is not optimized to compete with the glues currently used, due to the various problems at the production level. It´s advised to review the methods used with the glues currently used in the company, thus trying to improve its performance.
TipoDissertação de mestrado
DescriçãoDissertação de mestrado em Técnicas de Caracterização e Análise Química
URIhttps://hdl.handle.net/1822/84593
AcessoAcesso aberto
Aparece nas coleções:BUM - Dissertações de Mestrado

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Patricia Cristina Pinto dos Santos.pdf2,09 MBAdobe PDFVer/Abrir

Este trabalho está licenciado sob uma Licença Creative Commons Creative Commons

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID