Processing-induced performance limits of platinum resistance temperature detectors for reliable organ-on-a-chip sensing

dc.contributor.authorFerreira, Gabriel Malheiro
dc.contributor.authorSousa, Paulo Jorge Teixeira
dc.contributor.authorCatarino, Susana Oliveira
dc.contributor.authorMinas, Graça
dc.contributor.authorSousa, Patrícia C.
dc.date.accessioned2026-11-26T19:36:32Z
dc.date.issued2026
dc.description.abstractReliable temperature monitoring remains a critical bottleneck in Organ-on-a-Chip (OoC) systems, where integrated temperature sensors must provide electrical stability, biocompatible encapsulation, and efficient thermal coupling to the biological environment. While the effects of thermal annealing on platinum (Pt) thin films are well established, the influence of fabrication-related thermal budgets associated with OoC manufacturing has not been systematically correlated with device performance. Here, we establish a direct processing–microstructure–device performance relationship for Pt-based resistance temperature detectors (RTD). Using Si/Pt and Si/SiO2/Pt architectures, we investigate the impact of thermal annealing (up to 900°C) on film morphology and electrical properties and correlate them with device-level sensing performance. Moderate annealing temperatures (≈300°C), representative of oxide passivation processes, significantly improve electrical performance, reducing resistivity by up to 40% and increasing the temperature coefficient of resistance (TCR) through stress relaxation and grain coarsening. Higher annealing temperatures induce surface roughening and morphological instability, compromising sensor reliability. A SiO2 interlayer delays degradation and reduces resistivity drift, preserving film integrity under harsh thermal conditions. These results demonstrate that the thermal budget associated with dielectric passivation can be exploited to optimize RTD performance while defining practical processing windows for reliable integration into OoC and other biointegrated microsystems.eng
dc.description.sponsorshipThe authors acknowledge the financial support of the project HfPT – Health from Portugal, with reference n.º C644937233–00000047, cofunded by Component C5 – Capitalisation and Business Innovation under the Portuguese Resilience and Recovery Plan, through the Next GenerationEU Fund. This work was supported by the project PTDC/EEI-EEE/2846/2021 (https://doi.org/10.54499/PTDC/EEI-EEE/2846/2021), through national funds (OE), within the scope of the Scientific Research and Technological Development Projects (IC&DT) programme in all scientific domains (PTDC), through the Foundation for Science and Technology, I.P. (FCT, I.P.). This work was also partially supported by the projects COMPETE2030-FEDER-00689800, reference 2023.16645.ICDT (DOI https://doi.org/10.54499/2023.16645.ICDT), and COMPETE2030-FEDER-00712000, co-financed by the European Regional Development Fund (FEDER) and national funds through the Foundation for Science and Technology (FCT), under the Innovation and Digital Transition Programme – Compete2030. The authors also acknowledge the FCT financial support within the scope of the R&D Unit Project UID/4436/2025, LA/P/0029/2020. Gabriel M. Ferreira thanks the FCT for his Ph.D. grant, reference 2022.10519.BD. P.J.S. thanks the FCT for the contract funding provided through 2021.01086.CEECIND (https://doi.org/10.54499/2021.01086.CEECIND/CP1664/CT0008). The authors thank Aritz Retolaza for his help with the annealing measurements.
dc.distributioninternational
dc.identifier.articlenumber0:e70642
dc.identifier.citationFerreira, G. M., Sousa, P. J., Catarino, S. O., Minas, G., & Sousa, P. C. (2026). Processing‐Induced Performance Limits of Platinum Resistance Temperature Detectors for Reliable Organ‐On‐A‐Chip Sensing. Advanced Materials Interfaces, 13(18). https://doi.org/10.1002/admi.70642
dc.identifier.doi10.1002/admi.70642
dc.identifier.eissn2196-7350
dc.identifier.urihttps://hdl.handle.net/1822/104943
dc.language.isoeng
dc.peerreviewedyes
dc.publisherWiley
dc.relationMultiplexed micro(bio)sensors array integrated into an organ-on-a-chip device for assessing cancer NANOtherapy [PTDC/EEI-EEE/2846/2021]
dc.relationNovel multiplexer microfluidic platform for fast molecular diagnosis of stroke [2023.16645.ICDT]
dc.relationMicroelectromechanical Systems Research Unit [UID/04436/2025]
dc.relationAssociate Laboratory on Biotechnology, Bioengineering and microELectromechanical Systems [LA/P/0029/2020]
dc.relationTransducing system integrated into an organ-on-a-chip device for cancer nanotherapy monitoring [2022.10519.BD]
dc.relationMultiplexed micro(bio)sensors integrated into a microfluidic organ-on-a-chip platform for assessing innovative drug delivery [2021.01086.CEECIND/CP1664/CT0008]
dc.relation.hasversionhttps://advanced.onlinelibrary.wiley.com/doi/10.1002/admi.70642
dc.rightsopenAccess
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectannealing
dc.subjectmicrofabrication
dc.subjectplatinum
dc.subjectresistance-temperature-detectors
dc.subjectresistivity
dc.subject.fosEngenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática
dc.subject.odsSaúde de qualidade
dc.titleProcessing-induced performance limits of platinum resistance temperature detectors for reliable organ-on-a-chip sensingeng
dc.typearticle
dspace.entity.typePublication
oaire.awardNumberPTDC/EEI-EEE/2846/2021
oaire.awardNumber2023.16645.ICDT
oaire.awardNumberUID/04436/2025
oaire.awardNumberLA/P/0029/2020
oaire.awardNumber2022.10519.BD
oaire.awardNumber2021.01086.CEECIND/CP1664/CT0008
oaire.awardTitleMultiplexed micro(bio)sensors array integrated into an organ-on-a-chip device for assessing cancer NANOtherapy [PTDC/EEI-EEE/2846/2021]
oaire.awardTitleNovel multiplexer microfluidic platform for fast molecular diagnosis of stroke [2023.16645.ICDT]
oaire.awardTitleMicroelectromechanical Systems Research Unit [UID/04436/2025]
oaire.awardTitleAssociate Laboratory on Biotechnology, Bioengineering and microELectromechanical Systems [LA/P/0029/2020]
oaire.awardTitleTransducing system integrated into an organ-on-a-chip device for cancer nanotherapy monitoring [2022.10519.BD]
oaire.awardTitleMultiplexed micro(bio)sensors integrated into a microfluidic organ-on-a-chip platform for assessing innovative drug delivery [2021.01086.CEECIND/CP1664/CT0008]
oaire.awardURIhttps://hdl.handle.net/1822/99075
oaire.awardURIhttps://hdl.handle.net/1822/101519
oaire.awardURIhttps://hdl.handle.net/1822/100197
oaire.awardURIhttps://hdl.handle.net/1822/97179
oaire.awardURIhttps://hdl.handle.net/1822/101520
oaire.awardURIhttps://hdl.handle.net/1822/99512
oaire.citation.volumeAugust 2026
oaire.funderIdentifierhttp://doi.org/10.13039/501100001871
oaire.funderIdentifierhttp://doi.org/10.13039/501100001871
oaire.funderIdentifierhttp://doi.org/10.13039/501100001871
oaire.funderIdentifierhttp://doi.org/10.13039/501100001871
oaire.funderIdentifierhttp://doi.org/10.13039/501100001871
oaire.funderIdentifierhttp://doi.org/10.13039/501100001871
oaire.funderNameFundação para a Ciência e a Tecnologia, I.P.
oaire.funderNameFundação para a Ciência e a Tecnologia, I.P.
oaire.funderNameFundação para a Ciência e a Tecnologia, I.P.
oaire.funderNameFundação para a Ciência e a Tecnologia, I.P.
oaire.funderNameFundação para a Ciência e a Tecnologia, I.P.
oaire.funderNameFundação para a Ciência e a Tecnologia, I.P.
oaire.fundingStreamConcurso de Projetos IC&DT em Todos os Domínios Científicos
oaire.fundingStreamConcurso de Projetos de IC&DT em Todos os Domínios Científicos 2023
oaire.fundingStreamAvaliação UID 2023/2024
oaire.fundingStreamConcurso para Atribuição do Estatuto e Financiamento de Laboratórios Associados (LA)
oaire.fundingStreamCEEC IND4ed
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
relation.isProjectOfPublication087ea974-fbc5-469c-a93f-5cd33b967f3f
relation.isProjectOfPublication841784e7-369e-47a9-ab00-ed41b0d16880
relation.isProjectOfPublicationa8de3aeb-36cc-46dd-a56a-6ecf0305fe7d
relation.isProjectOfPublicatione6453fda-bc44-4538-917a-a94b535634c4
relation.isProjectOfPublication08160146-692b-456a-a855-400a71f32c1e
relation.isProjectOfPublication91c2c630-c00d-4fde-bc09-2a117998cc8a
relation.isProjectOfPublication.latestForDiscovery087ea974-fbc5-469c-a93f-5cd33b967f3f
sdum.journalAdvanced Materials Interfaces

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
ADVMAT.PDF
Tamanho:
4.5 MB
Formato:
Adobe Portable Document Format